Human Hepatitis A virus cellular receptor 2(HAVCR2) ELISA kit CSB-EL010145HU CUSABIO

$50.00
In stock
SKU
CSB-EL010145HU

Product Details

Target Namehepatitis A virus cellular receptor 2
Uniprot No.Q8TDQ0
SpeciesHomo sapiens (Human)
StorageStore at 2-8°C. Please refer to protocol.
Sensitivity11.75 pg/mL
Troubleshooting and FAQsELISA kit FAQs
Lead Time3-5 working days after you place the order, and it takes another 3-5 days for delivery via DHL or FedEx.
Associated namesCD366 ELISA Kit; FLJ14428 ELISA Kit; HAVcr-2 ELISA Kit; Havcr2 ELISA Kit; HAVR2_HUMAN ELISA Kit; Hepatitis A virus cellular receptor 2 ELISA Kit; Kidney injury molecule 3 ELISA Kit; KIM 3 ELISA Kit; KIM3 ELISA Kit; T cell immunoglobulin and mucin domain containing 3 ELISA Kit; T cell immunoglobulin mucin 3 ELISA Kit; T-cell immunoglobulin and mucin domain-containing protein 3 ELISA Kit; T-cell immunoglobulin mucin family member 3 ELISA Kit; T-cell immunoglobulin mucin receptor 3 ELISA Kit; T-cell membrane protein 3 ELISA Kit; Tim 3 ELISA Kit; TIM-3 ELISA Kit; TIM3 ELISA Kit; TIMD-3 ELISA Kit; TIMD3 ELISA Kit
AbbreviationHAVCR2
Sample Typesserum, plasma, tissue homogenates
Detection Range47 pg/mL-3000 pg/mL
Assay Time1-5h
Sample Loading Volume50-100ul
Detection Wavelength450 nm
Research AreaMicrobiology
Assay Principlequantitative
MeasurementSandwich
Precisionheaders: Intra-assay Precision (Precision within an assay): CV%<8%; rows: Intra-assay Precision (Precision within an assay): CV%<8%: Intra-assay Precision (Precision within an assay): CV%<8%; 1: Three samples of known concentration were tested twenty times on one plate to assess.; Intra-assay Precision (Precision within an assay): CV%<8%: Inter-assay Precision (Precision between assays): CV%<10%; 1: Three samples of known concentration were tested in twenty assays to assess.;
Linearityheaders: To assess the linearity of the assay, samples were spiked with high concentrations of human HAVCR2 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; rows: To assess the linearity of the assay, samples were spiked with high concentrations of human HAVCR2 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.: To assess the linearity of the assay, samples were spiked with high concentrations of human HAVCR2 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; 2: Sample; 3: Serum(n=4); 1: 1:1; 2: Average %; 3: 89; 1: Range %; 2: 86-94; 1: 1:2; 2: Average %; 3: 102; 1: Range %; 2: 95-105; 1: 1:4; 2: Average %; 3: 99; 1: Range %; 2: 95-108; 1: 1:8; 2: Average %; 3: 96; 1: Range %; 2: 86-104
Recoveryheaders: The recovery of human HAVCR2 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; rows: The recovery of human HAVCR2 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.: The recovery of human HAVCR2 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; 1: Sample Type; 2: Average % Recovery; 3: Range; 1: Serum (n=5); 2: 99; 3: 94-106; 1: EDTA plasma (n=4); 2: 94; 3: 90-98; ;
Typical Dataheaders: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; rows: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; 1: pg/ml OD1 OD2 Average Corrected 3000 2.301 2.195 2.248 2.145 1500 1.527 1.447 1.487 1.384 750 0.944 0.926 0.935 0.832 375 0.599 0.611 0.605 0.502 187.5 0.412 0.418 0.415 0.312 94 0.260 0.260 0.260 0.157 47 0.181 0.177 0.179 0.076 0 0.103 0.102 0.103; 2: pg/ml; 3: OD1; 4: OD2; 5: Average; 6: Corrected; 8: 3000; 9: 2.301; 10: 2.195; 11: 2.248; 12: 2.145; 14: 1500; 15: 1.527; 16: 1.447; 17: 1.487; 18: 1.384; 20: 750; 21: 0.944; 22: 0.926; 23: 0.935; 24: 0.832; 26: 375; 27: 0.599; 28: 0.611; 29: 0.605; 30: 0.502; 32: 187.5; 33: 0.412; 34: 0.418; 35: 0.415; 36: 0.312; 38: 94; 39: 0.260; 40: 0.260; 41: 0.260; 42: 0.157; 44: 47; 45: 0.181; 46: 0.177; 47: 0.179; 48: 0.076; 50: 0; 51: 0.103; 52: 0.102; 53: 0.103; 1: pg/ml; 2: OD1; 3: OD2; 4: Average; 5: Corrected; 1: 3000; 2: 2.301; 3: 2.195; 4: 2.248; 5: 2.145; 1: 1500; 2: 1.527; 3: 1.447; 4: 1.487; 5: 1.384; 1: 750; 2: 0.944; 3: 0.926; 4: 0.935; 5: 0.832; 1: 375; 2: 0.599; 3: 0.611; 4: 0.605; 5: 0.502; 1: 187.5; 2: 0.412; 3: 0.418; 4: 0.415; 5: 0.312; 1: 94; 2: 0.260; 3: 0.260; 4: 0.260; 5: 0.157; 1: 47; 2: 0.181; 3: 0.177; 4: 0.179; 5: 0.076; 1: 0; 2: 0.103; 3: 0.102; 4: 0.103
ELISA Data AnalysisELISA Standard Curve & Curve Expert software
Shelf Life6 months
DescriptionThis Human HAVCR2 ELISA Kit was designed for the quantitative measurement of Human HAVCR2 protein in serum, plasma, tissue homogenates. It is a Sandwich ELISA kit, its detection range is 47 pg/mL-3000 pg/mL and the sensitivity is 11.75 pg/mL .

MDSD

MSDS

Reviews

Write Your Own Review
You're reviewing:Human Hepatitis A virus cellular receptor 2(HAVCR2) ELISA kit CSB-EL010145HU CUSABIO
Your Rating
Copyright © 2025 Biogege, Inc. All rights reserved.