Human Mucin-4(MUC4) ELISA kit CSB-EL015227HU CUSABIO
$50.00
In stock
SKU
CSB-EL015227HU
Product Details
| Target Name | mucin 4, cell surface associated |
| Uniprot No. | Q99102 |
| Species | Homo sapiens (Human) |
| Storage | Store at 2-8°C. Please refer to protocol. |
| Sensitivity | 0.156 ng/mL |
| Troubleshooting and FAQs | ELISA kit FAQs |
| Lead Time | 3-5 working days after you place the order, and it takes another 3-5 days for delivery via DHL or FedEx. |
| Associated names | Ascites sialoglycoprotein 1 ELISA Kit; Ascites sialoglycoprotein 2 ELISA Kit; Ascites sialoglycoprotein ELISA Kit; ASGP ELISA Kit; ASGP-1 ELISA Kit; ASGP-2 ELISA Kit; HSA276359 ELISA Kit; MUC 4 ELISA Kit; MUC-4 ELISA Kit; Muc4 ELISA Kit; MUC4_HUMAN ELISA Kit; Mucin 4 ELISA Kit; Mucin 4 cell surface associated ELISA Kit; Mucin 4 tracheobronchial ELISA Kit; Mucin-4 beta chain ELISA Kit; Pancreatic adenocarcinoma mucin ELISA Kit; Testis mucin ELISA Kit; Tracheobronchial mucin ELISA Kit; Tracheobronchial mucin Fragment ELISA Kit |
| Abbreviation | MUC4 |
| Sample Types | serum, plasma, tissue homogenates |
| Detection Range | 0.625 ng/mL-40 ng/mL |
| Assay Time | 1-5h |
| Sample Loading Volume | 50-100ul |
| Detection Wavelength | 450 nm |
| Research Area | Signal Transduction |
| Assay Principle | quantitative |
| Measurement | Sandwich |
| Precision | headers: Intra-assay Precision (Precision within an assay): CV%<8%; rows: Intra-assay Precision (Precision within an assay): CV%<8%: Intra-assay Precision (Precision within an assay): CV%<8%; 1: Three samples of known concentration were tested twenty times on one plate to assess.; Intra-assay Precision (Precision within an assay): CV%<8%: Inter-assay Precision (Precision between assays): CV%<10%; 1: Three samples of known concentration were tested in twenty assays to assess.; |
| Linearity | headers: To assess the linearity of the assay, samples were spiked with high concentrations of human MUC4 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; rows: To assess the linearity of the assay, samples were spiked with high concentrations of human MUC4 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.: To assess the linearity of the assay, samples were spiked with high concentrations of human MUC4 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; 2: Sample; 3: Serum(n=4); 1: 1:1; 2: Average %; 3: 92; 1: Range %; 2: 89-96; 1: 1:2; 2: Average %; 3: 103; 1: Range %; 2: 98-107; 1: 1:4; 2: Average %; 3: 95; 1: Range %; 2: 89-99; 1: 1:8; 2: Average %; 3: 93; 1: Range %; 2: 86-97 |
| Recovery | headers: The recovery of human MUC4 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; rows: The recovery of human MUC4 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.: The recovery of human MUC4 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; 1: Sample Type; 2: Average % Recovery; 3: Range; 1: Serum (n=5); 2: 96; 3: 92-98; 1: EDTA plasma (n=4); 2: 88; 3: 82-94; ; |
| Typical Data | headers: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; rows: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; 1: ng/ml OD1 OD2 Average Corrected 40 2.235 2.354 2.295 2.163 20 1.816 1.705 1.761 1.629 10 1.224 1.247 1.236 1.104 5 0.801 0.823 0.812 0.680 2.5 0.453 0.464 0.459 0.327 1.25 0.312 0.324 0.318 0.186 0.625 0.224 0.228 0.226 0.094 0 0.131 0.132 0.132; 2: ng/ml; 3: OD1; 4: OD2; 5: Average; 6: Corrected; 8: 40; 9: 2.235; 10: 2.354; 11: 2.295; 12: 2.163; 14: 20; 15: 1.816; 16: 1.705; 17: 1.761; 18: 1.629; 20: 10; 21: 1.224; 22: 1.247; 23: 1.236; 24: 1.104; 26: 5; 27: 0.801; 28: 0.823; 29: 0.812; 30: 0.680; 32: 2.5; 33: 0.453; 34: 0.464; 35: 0.459; 36: 0.327; 38: 1.25; 39: 0.312; 40: 0.324; 41: 0.318; 42: 0.186; 44: 0.625; 45: 0.224; 46: 0.228; 47: 0.226; 48: 0.094; 50: 0; 51: 0.131; 52: 0.132; 53: 0.132; 1: ng/ml; 2: OD1; 3: OD2; 4: Average; 5: Corrected; 1: 40; 2: 2.235; 3: 2.354; 4: 2.295; 5: 2.163; 1: 20; 2: 1.816; 3: 1.705; 4: 1.761; 5: 1.629; 1: 10; 2: 1.224; 3: 1.247; 4: 1.236; 5: 1.104; 1: 5; 2: 0.801; 3: 0.823; 4: 0.812; 5: 0.680; 1: 2.5; 2: 0.453; 3: 0.464; 4: 0.459; 5: 0.327; 1: 1.25; 2: 0.312; 3: 0.324; 4: 0.318; 5: 0.186; 1: 0.625; 2: 0.224; 3: 0.228; 4: 0.226; 5: 0.094; 1: 0; 2: 0.131; 3: 0.132; 4: 0.132 |
| ELISA Data Analysis | ELISA Standard Curve & Curve Expert software |
| Shelf Life | 6 months |
| Description | This Human MUC4 ELISA Kit was designed for the quantitative measurement of Human MUC4 protein in serum, plasma, tissue homogenates. It is a Sandwich ELISA kit, its detection range is 0.625 ng/mL-40 ng/mL and the sensitivity is 0.156 ng/mL. |
MDSD