Human NAD (P)H Dehydrogenase, Quinone 1 (NQO1)ELISA Kit CSB-E14923h CUSABIO

$50.00
In stock
SKU
CSB-E14923h

Product Details

Target NameNAD(P)H dehydrogenase, quinone 1
Uniprot No.P15559
SpeciesHomo sapiens (Human)
StorageStore at 2-8°C. Please refer to protocol.
Sensitivity9.75 pg/mL
Troubleshooting and FAQsELISA kit FAQs
Lead Time3-5 working days after you place the order, and it takes another 3-5 days for delivery via DHL or FedEx.
Associated namesAzoreductase ELISA Kit; Cytochrome b 5 reductase ELISA Kit; DHQU ELISA Kit; DIA 4 ELISA Kit; DIA4 ELISA Kit; Diaphorase (NADH/NADPH) (cytochrome b 5 reductase) ELISA Kit; Diaphorase (NADH/NADPH) ELISA Kit; Diaphorase 4 ELISA Kit; Dioxin inducible 1 ELISA Kit; DT diaphorase ELISA Kit; DT-diaphorase ELISA Kit; DTD ELISA Kit; Menadione reductase ELISA Kit; NAD(P)H dehydrogenase [quinone] 1 ELISA Kit; NAD(P)H dehydrogenase quinone 1 ELISA Kit; NAD(P)H menadione oxidoreductase 1 dioxin inducible ELISA Kit; NAD(P)H quinone dehydrogenase 1 ELISA Kit; NAD(P)H: menadione oxidoreductase 1 dioxin inducible 1 ELISA Kit; NAD(P)H:menadione oxidoreductase 1 ELISA Kit; NAD(P)H:Quinone acceptor oxidoreductase type 1 ELISA Kit; NAD(P)H:quinone oxidoreductase 1 ELISA Kit; NAD(P)H:quinone oxireductase ELISA Kit; NMOR 1 ELISA Kit; NMOR I ELISA Kit; NMOR1 ELISA Kit; NMORI ELISA Kit; NQO 1 ELISA Kit; NQO1 ELISA Kit; NQO1_HUMAN ELISA Kit; Phylloquinone reductase ELISA Kit; QR 1 ELISA Kit; QR1 ELISA Kit; Quinone reductase 1 ELISA Kit
AbbreviationNQO1
Sample Typesserum, plasma, tissue homogenates, cell lysates
Detection Range39 pg/mL-2500 pg/mL
Assay Time1-5h
Sample Loading Volume50-100ul
Detection Wavelength450 nm
Research AreaMetabolism
Assay Principlequantitative
MeasurementSandwich
Precisionheaders: Intra-assay Precision (Precision within an assay): CV%<8%; rows: Intra-assay Precision (Precision within an assay): CV%<8%: Intra-assay Precision (Precision within an assay): CV%<8%; 1: Three samples of known concentration were tested twenty times on one plate to assess.; Intra-assay Precision (Precision within an assay): CV%<8%: Inter-assay Precision (Precision between assays): CV%<10%; 1: Three samples of known concentration were tested in twenty assays to assess.;
Linearityheaders: To assess the linearity of the assay, samples were spiked with high concentrations of human NQO1 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; rows: To assess the linearity of the assay, samples were spiked with high concentrations of human NQO1 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.: To assess the linearity of the assay, samples were spiked with high concentrations of human NQO1 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; 2: Sample; 3: Serum(n=4); 1: 1:1; 2: Average %; 3: 97; 1: Range %; 2: 89-101; 1: 1:2; 2: Average %; 3: 89; 1: Range %; 2: 91-94; 1: 1:4; 2: Average %; 3: 90; 1: Range %; 2: 82-94; 1: 1:8; 2: Average %; 3: 94; 1: Range %; 2: 84-99
Recoveryheaders: The recovery of human NQO1 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; rows: The recovery of human NQO1 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.: The recovery of human NQO1 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; 1: Sample Type; 2: Average % Recovery; 3: Range; 1: Serum (n=5); 2: 92; 3: 84-95; 1: EDTA plasma (n=4); 2: 99; 3: 91-103; ;
Typical Dataheaders: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; rows: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; 1: pg/ml OD1 OD2 Average Corrected 2500 2.633 2.551 2.592 2.450 1250 2.093 1.976 2.035 1.893 625 1.398 1.345 1.372 1.230 312 0.733 0.747 0.740 0.598 156 0.456 0.494 0.475 0.333 78 0.278 0.292 0.285 0.143 39 0.221 0.217 0.219 0.077 0 0.144 0.140 0.142; 2: pg/ml; 3: OD1; 4: OD2; 5: Average; 6: Corrected; 8: 2500; 9: 2.633; 10: 2.551; 11: 2.592; 12: 2.450; 14: 1250; 15: 2.093; 16: 1.976; 17: 2.035; 18: 1.893; 20: 625; 21: 1.398; 22: 1.345; 23: 1.372; 24: 1.230; 26: 312; 27: 0.733; 28: 0.747; 29: 0.740; 30: 0.598; 32: 156; 33: 0.456; 34: 0.494; 35: 0.475; 36: 0.333; 38: 78; 39: 0.278; 40: 0.292; 41: 0.285; 42: 0.143; 44: 39; 45: 0.221; 46: 0.217; 47: 0.219; 48: 0.077; 50: 0; 51: 0.144; 52: 0.140; 53: 0.142; 1: pg/ml; 2: OD1; 3: OD2; 4: Average; 5: Corrected; 1: 2500; 2: 2.633; 3: 2.551; 4: 2.592; 5: 2.450; 1: 1250; 2: 2.093; 3: 1.976; 4: 2.035; 5: 1.893; 1: 625; 2: 1.398; 3: 1.345; 4: 1.372; 5: 1.230; 1: 312; 2: 0.733; 3: 0.747; 4: 0.740; 5: 0.598; 1: 156; 2: 0.456; 3: 0.494; 4: 0.475; 5: 0.333; 1: 78; 2: 0.278; 3: 0.292; 4: 0.285; 5: 0.143; 1: 39; 2: 0.221; 3: 0.217; 4: 0.219; 5: 0.077; 1: 0; 2: 0.144; 3: 0.140; 4: 0.142
ELISA Data AnalysisELISA Standard Curve & Curve Expert software
Shelf Life6 months
DescriptionThis Human NQO1 ELISA Kit was designed for the quantitative measurement of Human NQO1 protein in serum, plasma, tissue homogenates, cell lysates. It is a Sandwich ELISA kit, its detection range is 39 pg/mL-2500 pg/mL and the sensitivity is 9.75 pg/mL.