Human Nuclease-sensitive element-binding protein 1(YBX1) ELISA kit CSB-EL026247HU CUSABIO

$50.00
In stock
SKU
CSB-EL026247HU

Product Details

Target NameY box binding protein 1
Uniprot No.P67809
SpeciesHomo sapiens (Human)
StorageStore at 2-8°C. Please refer to protocol.
Sensitivity7.8 pg/mL
Troubleshooting and FAQsELISA kit FAQs
Lead Time3-5 working days after you place the order, and it takes another 3-5 days for delivery via DHL or FedEx.
Associated namesBP 8 ELISA Kit; CBF-A ELISA Kit; CCAAT binding transcription factor I subunit A ELISA Kit; CCAAT-binding transcription factor I subunit A ELISA Kit; CSDA2 ELISA Kit; CSDB ELISA Kit; DBPB ELISA Kit; DNA binding protein B ELISA Kit; DNA-binding protein B ELISA Kit; EFI-A ELISA Kit; Enhancer factor I subunit A ELISA Kit; MDR NF1 ELISA Kit; MGC104858 ELISA Kit; MGC110976 ELISA Kit; MGC117250 ELISA Kit; NSEP 1 ELISA Kit; NSEP1 ELISA Kit; Nuclease sensitive element binding protein 1 ELISA Kit; Nuclease-sensitive element-binding protein 1 ELISA Kit; p50 ELISA Kit; Q15905 ELISA Kit; Y-box binding protein 1 ELISA Kit; Y-box transcription factor ELISA Kit; Y-box-binding protein 1 ELISA Kit; YB 1 ELISA Kit; YB-1 ELISA Kit; YBOX1_HUMAN ELISA Kit; YBX 1 ELISA Kit; ybx1 ELISA Kit
AbbreviationYBX1
Sample Typesserum, plasma, tissue homogenates, cell lysates
Detection Range31.25 pg/mL-2000 pg/mL
Assay Time1-5h
Sample Loading Volume50-100ul
Detection Wavelength450 nm
Research AreaEpigenetics and Nuclear Signaling
Assay Principlequantitative
MeasurementSandwich
Precisionheaders: Intra-assay Precision (Precision within an assay): CV%<8%; rows: Intra-assay Precision (Precision within an assay): CV%<8%: Intra-assay Precision (Precision within an assay): CV%<8%; 1: Three samples of known concentration were tested twenty times on one plate to assess.; Intra-assay Precision (Precision within an assay): CV%<8%: Inter-assay Precision (Precision between assays): CV%<10%; 1: Three samples of known concentration were tested in twenty assays to assess.;
Linearityheaders: To assess the linearity of the assay, samples were spiked with high concentrations of human YBX1 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; rows: To assess the linearity of the assay, samples were spiked with high concentrations of human YBX1 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.: To assess the linearity of the assay, samples were spiked with high concentrations of human YBX1 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; 2: Sample; 3: Serum(n=4); 1: 1:1; 2: Average %; 3: 89; 1: Range %; 2: 81-93; 1: 1:2; 2: Average %; 3: 102; 1: Range %; 2: 95-109; 1: 1:4; 2: Average %; 3: 95; 1: Range %; 2: 91-99; 1: 1:8; 2: Average %; 3: 86; 1: Range %; 2: 83-91
Recoveryheaders: The recovery of human YBX1 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; rows: The recovery of human YBX1 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.: The recovery of human YBX1 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; ; 1: Sample Type; 2: Average % Recovery; 3: Range; 1: Serum (n=5); 2: 104; 3: 101-109; 1: EDTA plasma (n=4); 2: 97; 3: 93-100; ;
Typical Dataheaders: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; rows: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; ; 1: pg/ml OD1 OD2 Average Corrected 2000 2.658 2.698 2.678 2.575 1000 2.381 2.451 2.416 2.313 500 1.974 1.962 1.968 1.865 250 1.229 1.169 1.199 1.096 125 0.698 0.687 0.693 0.590 62.5 0.400 0.412 0.406 0.303 31.25 0.209 0.211 0.210 0.107 0 0.101 0.105 0.103; 2: pg/ml; 3: OD1; 4: OD2; 5: Average; 6: Corrected; 9: 2000; 10: 2.658; 11: 2.698; 12: 2.678; 13: 2.575; 16: 1000; 17: 2.381; 18: 2.451; 19: 2.416; 20: 2.313; 23: 500; 24: 1.974; 25: 1.962; 26: 1.968; 27: 1.865; 30: 250; 31: 1.229; 32: 1.169; 33: 1.199; 34: 1.096; 37: 125; 38: 0.698; 39: 0.687; 40: 0.693; 41: 0.590; 44: 62.5; 45: 0.400; 46: 0.412; 47: 0.406; 48: 0.303; 51: 31.25; 52: 0.209; 53: 0.211; 54: 0.210; 55: 0.107; 58: 0; 59: 0.101; 60: 0.105; 61: 0.103; 1: pg/ml; 2: OD1; 3: OD2; 4: Average; 5: Corrected; 1: 2000; 2: 2.658; 3: 2.698; 4: 2.678; 5: 2.575; 1: 1000; 2: 2.381; 3: 2.451; 4: 2.416; 5: 2.313; 1: 500; 2: 1.974; 3: 1.962; 4: 1.968; 5: 1.865; 1: 250; 2: 1.229; 3: 1.169; 4: 1.199; 5: 1.096; 1: 125; 2: 0.698; 3: 0.687; 4: 0.693; 5: 0.590; 1: 62.5; 2: 0.400; 3: 0.412; 4: 0.406; 5: 0.303; 1: 31.25; 2: 0.209; 3: 0.211; 4: 0.210; 5: 0.107; 1: 0; 2: 0.101; 3: 0.105; 4: 0.103
ELISA Data AnalysisELISA Standard Curve & Curve Expert software
Shelf Life6 months
DescriptionThis Human YBX1 ELISA Kit was designed for the quantitative measurement of Human YBX1 protein in serum, plasma, tissue homogenates, cell lysates. It is a Sandwich ELISA kit, its detection range is 31.25 pg/mL-2000 pg/mL and the sensitivity is 7.8 pg/mL.

MDSD

MSDS

Reviews

Write Your Own Review
You're reviewing:Human Nuclease-sensitive element-binding protein 1(YBX1) ELISA kit CSB-EL026247HU CUSABIO
Your Rating
Copyright © 2025 Biogege, Inc. All rights reserved.