Human Peroxisome Proliferator-activated receptor γ,PPAR-γ ELISA Kit CSB-E08623h CUSABIO
$50.00
In stock
SKU
CSB-E08623h
Product Details
| Target Name | peroxisome proliferator-activated receptor gamma |
| Uniprot No. | P37231 |
| Species | Homo sapiens (Human) |
| Storage | Store at 2-8°C. Please refer to protocol. |
| Sensitivity | 19.5 pg/mL |
| Troubleshooting and FAQs | ELISA kit FAQs |
| Lead Time | 3-5 working days after you place the order, and it takes another 3-5 days for delivery via DHL or FedEx. |
| Associated names | CIMT1 ELISA Kit; GLM1 ELISA Kit; NR1C3 ELISA Kit; Nuclear receptor subfamily 1 group C member 3 ELISA Kit; OTTHUMP00000185032 ELISA Kit; OTTHUMP00000185036 ELISA Kit; Peroxisome proliferator activated nuclear receptor gamma variant 1 ELISA Kit; Peroxisome proliferator activated receptor gamma 1 ELISA Kit; Peroxisome Proliferator Activated Receptor gamma ELISA Kit; Peroxisome proliferator-activated receptor gamma ELISA Kit; PPAR gamma ELISA Kit; PPAR-gamma ELISA Kit; PPARG ELISA Kit; PPARG_HUMAN ELISA Kit; PPARG1 ELISA Kit; PPARG2 ELISA Kit; PPARgamma ELISA Kit |
| Abbreviation | PPARG |
| Sample Types | serum, plasma |
| Detection Range | 78 pg/mL-5000 pg/mL |
| Assay Time | 1-5h |
| Sample Loading Volume | 50-100ul |
| Detection Wavelength | 450 nm |
| Research Area | Metabolism |
| Assay Principle | quantitative |
| Measurement | Sandwich |
| Precision | headers: Intra-assay Precision (Precision within an assay): CV%<8%; rows: Intra-assay Precision (Precision within an assay): CV%<8%: Intra-assay Precision (Precision within an assay): CV%<8%; 1: Three samples of known concentration were tested twenty times on one plate to assess.; Intra-assay Precision (Precision within an assay): CV%<8%: Inter-assay Precision (Precision between assays): CV%<10%; 1: Three samples of known concentration were tested in twenty assays to assess.; |
| Linearity | headers: To assess the linearity of the assay, samples were spiked with high concentrations of human PPAR-γ in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; rows: To assess the linearity of the assay, samples were spiked with high concentrations of human PPAR-γ in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.: To assess the linearity of the assay, samples were spiked with high concentrations of human PPAR-γ in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; 2: Sample; 3: Serum(n=4); 1: 1:1; 2: Average %; 3: 93; 1: Range %; 2: 86-99; 1: 1:2; 2: Average %; 3: 94; 1: Range %; 2: 84-99; 1: 1:4; 2: Average %; 3: 90; 1: Range %; 2: 85-96; 1: 1:8; 2: Average %; 3: 86; 1: Range %; 2: 80-94 |
| Recovery | headers: The recovery of human PPAR-γ spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; rows: The recovery of human PPAR-γ spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.: The recovery of human PPAR-γ spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; 1: Sample Type; 2: Average % Recovery; 3: Range; 1: Serum (n=5); 2: 96; 3: 89-102; 1: EDTA plasma (n=4); 2: 89; 3: 84-92; ; |
| Typical Data | headers: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; rows: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; 1: pg/ml OD1 OD2 Average Corrected 5000 2.315 2.215 2.265 2.119 2500 1.817 1.717 1.767 1.621 1250 1.257 1.157 1.207 1.061 625 0.712 0.702 0.707 0.561 312 0.418 0.408 0.413 0.267 156 0.331 0.321 0.326 0.180 78 0.255 0.245 0.250 0.104 0 0.151 0.141 0.146; 2: pg/ml; 3: OD1; 4: OD2; 5: Average; 6: Corrected; 8: 5000; 9: 2.315; 10: 2.215; 11: 2.265; 12: 2.119; 14: 2500; 15: 1.817; 16: 1.717; 17: 1.767; 18: 1.621; 20: 1250; 21: 1.257; 22: 1.157; 23: 1.207; 24: 1.061; 26: 625; 27: 0.712; 28: 0.702; 29: 0.707; 30: 0.561; 32: 312; 33: 0.418; 34: 0.408; 35: 0.413; 36: 0.267; 38: 156; 39: 0.331; 40: 0.321; 41: 0.326; 42: 0.180; 44: 78; 45: 0.255; 46: 0.245; 47: 0.250; 48: 0.104; 50: 0; 51: 0.151; 52: 0.141; 53: 0.146; 1: pg/ml; 2: OD1; 3: OD2; 4: Average; 5: Corrected; 1: 5000; 2: 2.315; 3: 2.215; 4: 2.265; 5: 2.119; 1: 2500; 2: 1.817; 3: 1.717; 4: 1.767; 5: 1.621; 1: 1250; 2: 1.257; 3: 1.157; 4: 1.207; 5: 1.061; 1: 625; 2: 0.712; 3: 0.702; 4: 0.707; 5: 0.561; 1: 312; 2: 0.418; 3: 0.408; 4: 0.413; 5: 0.267; 1: 156; 2: 0.331; 3: 0.321; 4: 0.326; 5: 0.180; 1: 78; 2: 0.255; 3: 0.245; 4: 0.250; 5: 0.104; 1: 0; 2: 0.151; 3: 0.141; 4: 0.146 |
| ELISA Data Analysis | ELISA Standard Curve & Curve Expert software |
| Shelf Life | 6 months |
| Description | This Human PPARG ELISA Kit was designed for the quantitative measurement of Human PPARG protein in serum, plasma. It is a Sandwich ELISA kit, its detection range is 78 pg/mL-5000 pg/mL and the sensitivity is 19.5 pg/mL. |
MDSD