Human Phosphatidylethanolamine-binding protein 1(PEBP1) ELISA kit CSB-EL017766HU CUSABIO
$50.00
In stock
SKU
CSB-EL017766HU
Product Details
| Target Name | phosphatidylethanolamine binding protein 1 |
| Uniprot No. | P30086 |
| Species | Homo sapiens (Human) |
| Storage | Store at 2-8°C. Please refer to protocol. |
| Sensitivity | 0.039 ng/mL |
| Troubleshooting and FAQs | ELISA kit FAQs |
| Lead Time | 3-5 working days after you place the order, and it takes another 3-5 days for delivery via DHL or FedEx. |
| Associated names | Epididymis luminal protein 210 ELISA Kit; Epididymis secretory protein Li 34 ELISA Kit; Epididymis secretory protein Li 96 ELISA Kit; HCNP ELISA Kit; HCNPpp ELISA Kit; HEL 210 ELISA Kit; HEL S 34 ELISA Kit; HEL S 96 ELISA Kit; Hippocampal cholinergic neurostimulating peptide ELISA Kit; Neuropolypeptide h3 ELISA Kit; PBP ELISA Kit; PEBP ELISA Kit; PEBP 1 ELISA Kit; PEBP-1 ELISA Kit; Pebp1 ELISA Kit; PEBP1_HUMAN ELISA Kit; Phosphatidylethanolamine binding protein ELISA Kit; Phosphatidylethanolamine binding protein 1 ELISA Kit; Prostatic binding protein ELISA Kit; Prostatic-binding protein ELISA Kit; R kip ELISA Kit; Raf kinase inhibitor protein ELISA Kit; Raf kinase inhibitory protein ELISA Kit; RKIP ELISA Kit |
| Abbreviation | PEBP1 |
| Sample Types | serum, plasma, cell lysates |
| Detection Range | 0.156 ng/mL-10 ng/mL |
| Assay Time | 1-5h |
| Sample Loading Volume | 50-100ul |
| Detection Wavelength | 450 nm |
| Research Area | Cancer |
| Assay Principle | quantitative |
| Measurement | Sandwich |
| Precision | headers: Intra-assay Precision (Precision within an assay): CV%<8%; rows: Intra-assay Precision (Precision within an assay): CV%<8%: Intra-assay Precision (Precision within an assay): CV%<8%; 1: Three samples of known concentration were tested twenty times on one plate to assess.; Intra-assay Precision (Precision within an assay): CV%<8%: Inter-assay Precision (Precision between assays): CV%<10%; 1: Three samples of known concentration were tested in twenty assays to assess.; |
| Linearity | headers: To assess the linearity of the assay, samples were spiked with high concentrations of human PEBP1 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; rows: To assess the linearity of the assay, samples were spiked with high concentrations of human PEBP1 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.: To assess the linearity of the assay, samples were spiked with high concentrations of human PEBP1 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; 2: Sample; 3: Serum(n=4); 1: 1:1; 2: Average %; 3: 102; 1: Range %; 2: 89-107; 1: 1:2; 2: Average %; 3: 101; 1: Range %; 2: 96-105; 1: 1:4; 2: Average %; 3: 94; 1: Range %; 2: 87-98; 1: 1:8; 2: Average %; 3: 94; 1: Range %; 2: 87-99 |
| Recovery | headers: The recovery of human PEBP1 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; rows: The recovery of human PEBP1 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.: The recovery of human PEBP1 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; ; 1: Sample Type; 2: Average % Recovery; 3: Range; 1: Serum (n=5); 2: 102; 3: 93-106; 1: EDTA plasma (n=4); 2: 101; 3: 95-104; ; |
| Typical Data | headers: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; rows: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; ; 1: ng/ml OD1 OD2 Average Corrected 10 2.483 2.423 2.453 2.308 5 1.902 1.876 1.889 1.744 2.5 1.271 1.245 1.258 1.113 1.25 0.853 0.802 0.828 0.683 0.625 0.481 0.471 0.476 0.331 0.312 0.336 0.328 0.332 0.187 0.156 0.241 0.234 0.238 0.093 0 0.148 0.142 0.145; 2: ng/ml; 3: OD1; 4: OD2; 5: Average; 6: Corrected; 9: 10; 10: 2.483; 11: 2.423; 12: 2.453; 13: 2.308; 16: 5; 17: 1.902; 18: 1.876; 19: 1.889; 20: 1.744; 23: 2.5; 24: 1.271; 25: 1.245; 26: 1.258; 27: 1.113; 30: 1.25; 31: 0.853; 32: 0.802; 33: 0.828; 34: 0.683; 37: 0.625; 38: 0.481; 39: 0.471; 40: 0.476; 41: 0.331; 44: 0.312; 45: 0.336; 46: 0.328; 47: 0.332; 48: 0.187; 51: 0.156; 52: 0.241; 53: 0.234; 54: 0.238; 55: 0.093; 58: 0; 59: 0.148; 60: 0.142; 61: 0.145; 1: ng/ml; 2: OD1; 3: OD2; 4: Average; 5: Corrected; 1: 10; 2: 2.483; 3: 2.423; 4: 2.453; 5: 2.308; 1: 5; 2: 1.902; 3: 1.876; 4: 1.889; 5: 1.744; 1: 2.5; 2: 1.271; 3: 1.245; 4: 1.258; 5: 1.113; 1: 1.25; 2: 0.853; 3: 0.802; 4: 0.828; 5: 0.683; 1: 0.625; 2: 0.481; 3: 0.471; 4: 0.476; 5: 0.331; 1: 0.312; 2: 0.336; 3: 0.328; 4: 0.332; 5: 0.187; 1: 0.156; 2: 0.241; 3: 0.234; 4: 0.238; 5: 0.093; 1: 0; 2: 0.148; 3: 0.142; 4: 0.145 |
| ELISA Data Analysis | ELISA Standard Curve & Curve Expert software |
| Shelf Life | 6 months |
| Description | This Human PEBP1 ELISA Kit was designed for the quantitative measurement of Human PEBP1 protein in serum, plasma, cell lysates. It is a Sandwich ELISA kit, its detection range is 0.156 ng/mL-10 ng/mL and the sensitivity is 0.039 ng/mL. |
MDSD