Human inter-alpha-trypsin inhibitor heavy chain H1(ITIH1) ELISA Kit CSB-E13743h CUSABIO

$50.00
In stock
SKU
CSB-E13743h

Product Details

Target Nameinter-alpha (globulin) inhibitor H1
Uniprot No.P19827
SpeciesHomo sapiens (Human)
StorageStore at 2-8°C. Please refer to protocol.
Sensitivity3.9 ng/mL
Troubleshooting and FAQsELISA kit FAQs
Lead Time3-5 working days after you place the order, and it takes another 3-5 days for delivery via DHL or FedEx.
Associated namesH1P ELISA Kit; IATIH ELISA Kit; IGHEP1 ELISA Kit; Inter alpha (globulin) inhibitor H1 ELISA Kit; Inter alpha (globulin) inhibitor H1 polypeptide ELISA Kit; Inter alpha trypsin inhibitor heavy chain 1 ELISA Kit; Inter alpha trypsin inhibitor heavy chain H1 ELISA Kit; Inter-alpha-inhibitor heavy chain 1 ELISA Kit; Inter-alpha-trypsin inhibitor complex component III ELISA Kit; Inter-alpha-trypsin inhibitor heavy chain H1 ELISA Kit; ITI heavy chain H1 ELISA Kit; ITI-HC1 ELISA Kit; ITIH ELISA Kit; ITIH1 ELISA Kit; ITIH1_HUMAN ELISA Kit; Serum-derived hyaluronan-associated protein ELISA Kit; SHAP ELISA Kit
AbbreviationITIH1
Sample Typesserum, plasma, cell culture supernates, urine, tissue homogenates
Detection Range15.6 ng/mL-1000 ng/mL
Assay Time1-5h
Sample Loading Volume50-100ul
Detection Wavelength450 nm
Research AreaCell Biology
Assay Principlequantitative
MeasurementSandwich
Precisionheaders: Intra-assay Precision (Precision within an assay): CV%<8%; rows: Intra-assay Precision (Precision within an assay): CV%<8%: Intra-assay Precision (Precision within an assay): CV%<8%; 1: Three samples of known concentration were tested twenty times on one plate to assess.; Intra-assay Precision (Precision within an assay): CV%<8%: Inter-assay Precision (Precision between assays): CV%<10%; 1: Three samples of known concentration were tested in twenty assays to assess.;
Linearityheaders: To assess the linearity of the assay, samples were spiked with high concentrations of human ITIH1 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; rows: To assess the linearity of the assay, samples were spiked with high concentrations of human ITIH1 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.: To assess the linearity of the assay, samples were spiked with high concentrations of human ITIH1 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; 2: Sample; 3: Serum(n=4); 1: 1:100; 2: Average %; 3: 86; 1: Range %; 2: 80-92; 1: 1:200; 2: Average %; 3: 97; 1: Range %; 2: 91-105; 1: 1:400; 2: Average %; 3: 99; 1: Range %; 2: 92-110; 1: 1:800; 2: Average %; 3: 97; 1: Range %; 2: 86-98
Recoveryheaders: The recovery of human ITIH1 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; rows: The recovery of human ITIH1 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.: The recovery of human ITIH1 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; 1: Sample Type; 2: Average % Recovery; 3: Range; 1: Serum (n=5); 2: 93; 3: 89-98; 1: EDTA plasma (n=4); 2: 97; 3: 90-104; ;
Typical Dataheaders: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; rows: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; 1: ng/ml OD1 OD2 Average Corrected 1000 2.400 2.418 2.409 2.328 500 2.088 1.999 2.004 1.923 250 1.562 1.555 1.559 1.478 125 1.228 1.211 1.220 1.139 62.5 0.689 0.665 0.677 0.596 31.25 0.452 0.436 0.444 0.363 15.6 0.270 0.254 0.262 0.181 0 0.084 0.078 0.081; 2: ng/ml; 3: OD1; 4: OD2; 5: Average; 6: Corrected; 8: 1000; 9: 2.400; 10: 2.418; 11: 2.409; 12: 2.328; 14: 500; 15: 2.088; 16: 1.999; 17: 2.004; 18: 1.923; 20: 250; 21: 1.562; 22: 1.555; 23: 1.559; 24: 1.478; 26: 125; 27: 1.228; 28: 1.211; 29: 1.220; 30: 1.139; 32: 62.5; 33: 0.689; 34: 0.665; 35: 0.677; 36: 0.596; 38: 31.25; 39: 0.452; 40: 0.436; 41: 0.444; 42: 0.363; 44: 15.6; 45: 0.270; 46: 0.254; 47: 0.262; 48: 0.181; 50: 0; 51: 0.084; 52: 0.078; 53: 0.081; 1: ng/ml; 2: OD1; 3: OD2; 4: Average; 5: Corrected; 1: 1000; 2: 2.400; 3: 2.418; 4: 2.409; 5: 2.328; 1: 500; 2: 2.088; 3: 1.999; 4: 2.004; 5: 1.923; 1: 250; 2: 1.562; 3: 1.555; 4: 1.559; 5: 1.478; 1: 125; 2: 1.228; 3: 1.211; 4: 1.220; 5: 1.139; 1: 62.5; 2: 0.689; 3: 0.665; 4: 0.677; 5: 0.596; 1: 31.25; 2: 0.452; 3: 0.436; 4: 0.444; 5: 0.363; 1: 15.6; 2: 0.270; 3: 0.254; 4: 0.262; 5: 0.181; 1: 0; 2: 0.084; 3: 0.078; 4: 0.081
ELISA Data AnalysisELISA Standard Curve & Curve Expert software
Shelf Life6 months
DescriptionThis Human ITIH1 ELISA Kit was designed for the quantitative measurement of Human ITIH1 protein in serum, plasma, cell culture supernates, urine, tissue homogenates. It is a Sandwich ELISA kit, its detection range is 15.6 ng/mL-1000 ng/mL and the sensitivity is 3.9 ng/mL .

MDSD

MSDS

Reviews

Write Your Own Review
You're reviewing:Human inter-alpha-trypsin inhibitor heavy chain H1(ITIH1) ELISA Kit CSB-E13743h CUSABIO
Your Rating
Copyright © 2025 Biogege, Inc. All rights reserved.