Human leukocyte antigen G,HLA-G ELISA Kit CSB-E09401h CUSABIO

$50.00
In stock
SKU
CSB-E09401h

Product Details

Target Namemajor histocompatibility complex, class I, G
Uniprot No.P17693
SpeciesHomo sapiens (Human)
StorageStore at 2-8°C. Please refer to protocol.
Sensitivity0.31 ng/mL
Troubleshooting and FAQsELISA kit FAQs
Lead Time3-5 working days after you place the order, and it takes another 3-5 days for delivery via DHL or FedEx.
Associated namesB2 microglobulin ELISA Kit; DADB-15K14.8 ELISA Kit; HLA 6.0 ELISA Kit; HLA class I histocompatibility antigen alpha chain G ELISA Kit; HLA class I histocompatibility antigen; alpha chain G ELISA Kit; HLA class I molecule ELISA Kit; HLA G ELISA Kit; HLA G antigen ELISA Kit; HLA G histocompatibility antigen class I G ELISA Kit; HLA G3 ELISA Kit; HLA-G ELISA Kit; HLA-G histocompatibility antigen; class I ELISA Kit; HLA60 ELISA Kit; HLAG ELISA Kit; HLAG_HUMAN ELISA Kit; Major histocompatibility complex class I G ELISA Kit; MHC class I antigen ELISA Kit; MHC class I antigen G ELISA Kit; MHC G ELISA Kit; T-cell A locus ELISA Kit; TCA ELISA Kit
AbbreviationHLA-G
Sample Typesserum, plasma, tissue homogenates
Detection Range1.25 ng/mL-80 ng/mL
Assay Time1-5h
Sample Loading Volume50-100ul
Detection Wavelength450 nm
Research AreaImmunology
Assay Principlequantitative
MeasurementSandwich
Precisionheaders: Intra-assay Precision (Precision within an assay): CV%<8%; rows: Intra-assay Precision (Precision within an assay): CV%<8%: Intra-assay Precision (Precision within an assay): CV%<8%; 1: Three samples of known concentration were tested twenty times on one plate to assess.; Intra-assay Precision (Precision within an assay): CV%<8%: Inter-assay Precision (Precision between assays): CV%<10%; 1: Three samples of known concentration were tested in twenty assays to assess.;
Linearityheaders: To assess the linearity of the assay, samples were spiked with high concentrations of human HLA-G in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; rows: To assess the linearity of the assay, samples were spiked with high concentrations of human HLA-G in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.: To assess the linearity of the assay, samples were spiked with high concentrations of human HLA-G in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; 2: Sample; 3: Serum(n=4); 1: 1:1; 2: Average %; 3: 93; 1: Range %; 2: 86-98; 1: 1:2; 2: Average %; 3: 103; 1: Range %; 2: 97-108; 1: 1:4; 2: Average %; 3: 93; 1: Range %; 2: 85-98; 1: 1:8; 2: Average %; 3: 97; 1: Range %; 2: 91-101
Recoveryheaders: The recovery of human HLA-G spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; rows: The recovery of human HLA-G spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.: The recovery of human HLA-G spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; 1: Sample Type; 2: Average % Recovery; 3: Range; 1: Serum (n=5); 2: 86; 3: 80-94; 1: EDTA plasma (n=4); 2: 96; 3: 92-104; ;
Typical Dataheaders: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; rows: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; 1: ng/ml OD1 OD2 Average Corrected 80 2.961 2.960 2.961 2.828 40 2.252 2.205 2.229 2.096 20 1.266 1.286 1.276 1.143 10 0.731 0.755 0.743 0.610 5 0.368 0.400 0.384 0.251 2.5 0.302 0.322 0.312 0.179 1.25 0.227 0.215 0.221 0.088 0 0.134 0.132 0.133; 2: ng/ml; 3: OD1; 4: OD2; 5: Average; 6: Corrected; 8: 80; 9: 2.961; 10: 2.960; 11: 2.961; 12: 2.828; 14: 40; 15: 2.252; 16: 2.205; 17: 2.229; 18: 2.096; 20: 20; 21: 1.266; 22: 1.286; 23: 1.276; 24: 1.143; 26: 10; 27: 0.731; 28: 0.755; 29: 0.743; 30: 0.610; 32: 5; 33: 0.368; 34: 0.400; 35: 0.384; 36: 0.251; 38: 2.5; 39: 0.302; 40: 0.322; 41: 0.312; 42: 0.179; 44: 1.25; 45: 0.227; 46: 0.215; 47: 0.221; 48: 0.088; 50: 0; 51: 0.134; 52: 0.132; 53: 0.133; 1: ng/ml; 2: OD1; 3: OD2; 4: Average; 5: Corrected; 1: 80; 2: 2.961; 3: 2.960; 4: 2.961; 5: 2.828; 1: 40; 2: 2.252; 3: 2.205; 4: 2.229; 5: 2.096; 1: 20; 2: 1.266; 3: 1.286; 4: 1.276; 5: 1.143; 1: 10; 2: 0.731; 3: 0.755; 4: 0.743; 5: 0.610; 1: 5; 2: 0.368; 3: 0.400; 4: 0.384; 5: 0.251; 1: 2.5; 2: 0.302; 3: 0.322; 4: 0.312; 5: 0.179; 1: 1.25; 2: 0.227; 3: 0.215; 4: 0.221; 5: 0.088; 1: 0; 2: 0.134; 3: 0.132; 4: 0.133
Materials providedA micro ELISA plate ---The 96-well plate has been pre-coated with an anti-human HLA-G antibody. This dismountable microplate can be divided into 12 x 8 strip plates. Two vials lyophilized standard ---Dilute a bottle of the standard at dilution series, read the OD values, and then draw a standard curve. One vial Biotin-labeled HLA-G antibody (100 x concentrate) (120 μl/bottle) ---Act as the detection antibody. One vial HRP-avidin (100 x concentrate) (120 μl/bottle) ---Bind to the detection antibody and react with the TMB substrate to make the solution chromogenic. One vial Biotin-antibody Diluent (15 ml/bottle) ---Dilute the Biotin-antibody. One vial HRP-avidin Diluent (15 ml/bottle) ---Dilute the HRP-avidin solution. One vial Sample Diluent (50 ml/bottle)---Dilute the sample to an appropriate concentration. One vial Wash Buffer (25 x concentrate) (20 ml/bottle) ---Wash away unbound or free substances. One vial TMB Substrate (10 ml/bottle) ---Act as the chromogenic agent. TMB interacts with HRP, eliciting the solution turns blue. One vial Stop Solution (10 ml/bottle) ---Stop the color reaction. The solution color immediately turns from blue to yellow. Four Adhesive Strips (For 96 wells) --- Cover the microplate when incubation. An instruction manual
Materials not providedA microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 540 nm or 570 nm. An incubator can provide stable incubation conditions up to 37°C±5°C. Centrifuge Vortex Squirt bottle, manifold dispenser, or automated microplate washer Absorbent paper for blotting the microtiter plate 50-300ul multi-channel micropipette Pipette tips Single-channel micropipette with different ranges 100ml and 500ml graduated cylinders Deionized or distilled water Timer Test tubes for dilution
ELISA Data AnalysisELISA Standard Curve & Curve Expert software
Shelf Life6 months
DescriptionThis Human HLA-G ELISA Kit was designed for the quantitative measurement of Human HLA-G protein in serum, plasma, tissue homogenates. It is a Sandwich ELISA kit, its detection range is 1.25 ng/mL-80 ng/mL and the sensitivity is 0.31 ng/mL .

MDSD

MSDS

Reviews

Write Your Own Review
You're reviewing:Human leukocyte antigen G,HLA-G ELISA Kit CSB-E09401h CUSABIO
Your Rating
Copyright © 2025 Biogege, Inc. All rights reserved.