Human regenerating gene Ⅳ,REG-4 ELISA Kit CSB-E11890h CUSABIO

$50.00
In stock
SKU
CSB-E11890h

Product Details

Target Nameregenerating islet-derived family, member 4
Uniprot No.Q9BYZ8
SpeciesHomo sapiens (Human)
StorageStore at 2-8°C. Please refer to protocol.
Sensitivity0.078 ng/mL
Troubleshooting and FAQsELISA kit FAQs
Lead Time3-5 working days after you place the order, and it takes another 3-5 days for delivery via DHL or FedEx.
Associated namesGastrointestinal secretory protein ELISA Kit; GISP ELISA Kit; Reg IV ELISA Kit; REG like protein ELISA Kit; REG-4 ELISA Kit; REG-like protein ELISA Kit; Reg4 ELISA Kit; REG4_HUMAN ELISA Kit; Regenerating gene type IV ELISA Kit; Regenerating islet derived family member 4 ELISA Kit; Regenerating islet derived protein 4 precursor ELISA Kit; Regenerating islet-derived protein 4 ELISA Kit; Regenerating islet-derived protein IV ELISA Kit; REGIV ELISA Kit; RELP ELISA Kit
AbbreviationREG4
Sample Typesserum, plasma, tissue homogenates
Detection Range0.312 ng/mL-20 ng/mL
Assay Time1-5h
Sample Loading Volume50-100ul
Detection Wavelength450 nm
Research AreaImmunology
Assay Principlequantitative
MeasurementSandwich
Precisionheaders: Intra-assay Precision (Precision within an assay): CV%<8%; rows: Intra-assay Precision (Precision within an assay): CV%<8%: Intra-assay Precision (Precision within an assay): CV%<8%; 1: Three samples of known concentration were tested twenty times on one plate to assess.; Intra-assay Precision (Precision within an assay): CV%<8%: Inter-assay Precision (Precision between assays): CV%<10%; 1: Three samples of known concentration were tested in twenty assays to assess.;
Linearityheaders: To assess the linearity of the assay, samples were spiked with high concentrations of human REG-4 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; rows: To assess the linearity of the assay, samples were spiked with high concentrations of human REG-4 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.: To assess the linearity of the assay, samples were spiked with high concentrations of human REG-4 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; 2: Sample; 3: Serum(n=4); 1: 1:1; 2: Average %; 3: 87; 1: Range %; 2: 83-92; 1: 1:2; 2: Average %; 3: 92; 1: Range %; 2: 90-95; 1: 1:4; 2: Average %; 3: 96; 1: Range %; 2: 93-99; 1: 1:8; 2: Average %; 3: 95; 1: Range %; 2: 88-98
Recoveryheaders: The recovery of human REG-4 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; rows: The recovery of human REG-4 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.: The recovery of human REG-4 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; 1: Sample Type; 2: Average % Recovery; 3: Range; 1: Serum (n=5); 2: 91; 3: 89-94; 1: EDTA plasma (n=4); 2: 92; 3: 90-94; ;
Typical Dataheaders: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; rows: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; 1: ng/ml OD1 OD2 Average Corrected 20 2.832 2.801 2.817 2.676 10 2.238 2.187 2.213 2.072 5 1.419 1.385 1.402 1.261 2.5 0.673 0.654 0.664 0.523 1.25 0.434 0.411 0.423 0.282 0.625 0.281 0.269 0.275 0.134 0.312 0.211 0.202 0.207 0.066 0 0.143 0.139 0.141; 2: ng/ml; 3: OD1; 4: OD2; 5: Average; 6: Corrected; 8: 20; 9: 2.832; 10: 2.801; 11: 2.817; 12: 2.676; 14: 10; 15: 2.238; 16: 2.187; 17: 2.213; 18: 2.072; 20: 5; 21: 1.419; 22: 1.385; 23: 1.402; 24: 1.261; 26: 2.5; 27: 0.673; 28: 0.654; 29: 0.664; 30: 0.523; 32: 1.25; 33: 0.434; 34: 0.411; 35: 0.423; 36: 0.282; 38: 0.625; 39: 0.281; 40: 0.269; 41: 0.275; 42: 0.134; 44: 0.312; 45: 0.211; 46: 0.202; 47: 0.207; 48: 0.066; 50: 0; 51: 0.143; 52: 0.139; 53: 0.141; 1: ng/ml; 2: OD1; 3: OD2; 4: Average; 5: Corrected; 1: 20; 2: 2.832; 3: 2.801; 4: 2.817; 5: 2.676; 1: 10; 2: 2.238; 3: 2.187; 4: 2.213; 5: 2.072; 1: 5; 2: 1.419; 3: 1.385; 4: 1.402; 5: 1.261; 1: 2.5; 2: 0.673; 3: 0.654; 4: 0.664; 5: 0.523; 1: 1.25; 2: 0.434; 3: 0.411; 4: 0.423; 5: 0.282; 1: 0.625; 2: 0.281; 3: 0.269; 4: 0.275; 5: 0.134; 1: 0.312; 2: 0.211; 3: 0.202; 4: 0.207; 5: 0.066; 1: 0; 2: 0.143; 3: 0.139; 4: 0.141
ELISA Data AnalysisELISA Standard Curve & Curve Expert software
Shelf Life6 months
DescriptionThis Human REG4 ELISA Kit was designed for the quantitative measurement of Human REG4 protein in serum, plasma, tissue homogenates. It is a Sandwich ELISA kit, its detection range is 0.312 ng/mL-20 ng/mL and the sensitivity is 0.078 ng/mL.

MDSD

MSDS

Reviews

Write Your Own Review
You're reviewing:Human regenerating gene Ⅳ,REG-4 ELISA Kit CSB-E11890h CUSABIO
Your Rating
Copyright © 2025 Biogege, Inc. All rights reserved.