Human thymic stromal lymphopoietin,TSLP ELISA Kit CSB-E09316h CUSABIO
$50.00
In stock
SKU
CSB-E09316h
Product Details
| Uniprot No. | Q969D9 |
| Species | Homo sapiens (Human) |
| Storage | Store at 2-8°C. Please refer to protocol. |
| Sensitivity | 0.078 ng/ml |
| Troubleshooting and FAQs | ELISA kit FAQs |
| Lead Time | 3-5 working days after you place the order, and it takes another 3-5 days for delivery via DHL or FedEx. |
| Associated names | Thymic stromal lymphopoietin ELISA Kit; Thymic stromal lymphopoietin protein TSLP ELISA Kit; Tslp ELISA Kit; TSLP protein ELISA Kit; TSLP_HUMAN ELISA Kit |
| Abbreviation | TSLP |
| Sample Types | serum, plasma, tissue homogenates. |
| Detection Range | 0.312 ng/ml-20 ng/ml |
| Assay Time | 1-5h |
| Sample Loading Volume | 50-100ul |
| Detection Wavelength | 450 nm |
| Research Area | Immunology |
| Assay Principle | quantitative |
| Measurement | Sandwich |
| Precision | headers: Intra-assay Precision (Precision within an assay): CV%<8%; rows: Intra-assay Precision (Precision within an assay): CV%<8%: Intra-assay Precision (Precision within an assay): CV%<8%; 1: Three samples of known concentration were tested twenty times on one plate to assess.; Intra-assay Precision (Precision within an assay): CV%<8%: Inter-assay Precision (Precision between assays): CV%<10%; 1: Three samples of known concentration were tested in twenty assays to assess. |
| Linearity | headers: To assess the linearity of the assay, samples were spiked with high concentrations of human TSLP in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; rows: To assess the linearity of the assay, samples were spiked with high concentrations of human TSLP in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.: To assess the linearity of the assay, samples were spiked with high concentrations of human TSLP in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; 2: Sample; 3: Serum(n=4); 1: 1:1; 2: Average %; 3: 90; 1: Range %; 2: 84-97; 1: 1:2; 2: Average %; 3: 92; 1: Range %; 2: 86-99; 1: 1:4; 2: Average %; 3: 91; 1: Range %; 2: 84-98; 1: 1:8; 2: Average %; 3: 93; 1: Range %; 2: 86-98 |
| Recovery | headers: The recovery of human TSLP spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; rows: The recovery of human TSLP spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.: The recovery of human TSLP spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; 1: Sample Type; 2: Average % Recovery; 3: Range; 1: Serum (n=5); 2: 95; 3: 89-98; 1: EDTA plasma (n=4); 2: 92; 3: 86-97 |
| Typical Data | headers: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; rows: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; ; ; 1: ng/ml; 2: OD1; 3: OD2; 4: Average; 5: Corrected; 1: 20; 2: 3.002; 3: 2.934; 4: 2.968; 5: 2.786; 1: 10; 2: 1.935; 3: 1.867; 4: 1.901; 5: 1.719; 1: 5; 2: 1.163; 3: 1.128; 4: 1.146; 5: 0.964; 1: 2.5; 2: 0.734; 3: 0.729; 4: 0.732; 5: 0.550; 1: 1.25; 2: 0.406; 3: 0.421; 4: 0.413; 5: 0.231; 1: 0.625; 2: 0.306; 3: 0.293; 4: 0.299; 5: 0.118; 1: 0.312; 2: 0.246; 3: 0.254; 4: 0.250; 5: 0.068; 1: 0; 2: 0.179; 3: 0.185; 4: 0.182 |
| Materials provided | A micro ELISA plate ---The 96-well plate has been pre-coated with an anti-human TSLP antibody. This dismountable microplate can be divided into 12 x 8 strip plates. Two vials lyophilized standard ---Dilute a bottle of the standard at dilution series, read the OD values, and then draw a standard curve. One vial Biotin-labeled TSLP antibody (100 x concentrate) (120 μl/bottle) ---Act as the detection antibody. One vial HRP-avidin (100 x concentrate) (120 μl/bottle) ---Bind to the detection antibody and react with the TMB substrate to make the solution chromogenic. One vial Biotin-antibody Diluent (15 ml/bottle) ---Dilute the Biotin-antibody. One vial HRP-avidin Diluent (15 ml/bottle) ---Dilute the HRP-avidin solution. One vial Sample Diluent (50 ml/bottle)---Dilute the sample to an appropriate concentration. One vial Wash Buffer (25 x concentrate) (20 ml/bottle) ---Wash away unbound or free substances. One vial TMB Substrate (10 ml/bottle) ---Act as the chromogenic agent. TMB interacts with HRP, eliciting the solution turns blue. One vial Stop Solution (10 ml/bottle) ---Stop the color reaction. The solution color immediately turns from blue to yellow. Four Adhesive Strips (For 96 wells) --- Cover the microplate when incubation. An instruction manual |
| Materials not provided | A microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 540 nm or 570 nm. An incubator can provide stable incubation conditions up to 37°C±5°C. Centrifuge Vortex Squirt bottle, manifold dispenser, or automated microplate washer Absorbent paper for blotting the microtiter plate 50-300ul multi-channel micropipette Pipette tips Single-channel micropipette with different ranges 100ml and 500ml graduated cylinders Deionized or distilled water Timer Test tubes for dilution |
| ELISA Data Analysis | ELISA Standard Curve & Curve Expert software |
| Shelf Life | 6 months |
| Description | This Human TSLP ELISA Kit was designed for the quantitative measurement of Human TSLP protein in serum, tissue homogenates. It is a Sandwich ELISA kit, its detection range is 0.312 ng/ml-20 ng/ml and the sensitivity is 0.078 ng/ml. |