Mouse E-Selectin ELISA kit CSB-E04541m CUSABIO
$50.00
In stock
SKU
CSB-E04541m
Product Details
| Target Name | selectin E |
| Uniprot No. | Q00690 |
| Species | Mus musculus (Mouse) |
| Storage | Store at 2-8°C. Please refer to protocol. |
| Sensitivity | 19.5 pg/mL |
| Troubleshooting and FAQs | ELISA kit FAQs |
| Lead Time | 3-5 working days after you place the order, and it takes another 3-5 days for delivery via DHL or FedEx. |
| Associated names | Sele ELISA Kit; Elam-1 ELISA Kit; E-selectin ELISA Kit; CD62 antigen-like family member E ELISA Kit; Endothelial leukocyte adhesion molecule 1 ELISA Kit; ELAM-1 ELISA Kit; Leukocyte-endothelial cell adhesion molecule 2 ELISA Kit; LECAM2 ELISA Kit; CD antigen CD62E ELISA Kit |
| Abbreviation | SELE |
| Sample Types | serum, plasma, tissue homogenates |
| Detection Range | 78 pg/mL-5000 pg/mL |
| Assay Time | 1-5h |
| Sample Loading Volume | 50-100ul |
| Detection Wavelength | 450 nm |
| Research Area | Immunology |
| Assay Principle | quantitative |
| Measurement | Sandwich |
| Precision | headers: Intra-assay Precision (Precision within an assay): CV%<8%; rows: Intra-assay Precision (Precision within an assay): CV%<8%: Intra-assay Precision (Precision within an assay): CV%<8%; 1: Three samples of known concentration were tested twenty times on one plate to assess.; Intra-assay Precision (Precision within an assay): CV%<8%: Inter-assay Precision (Precision between assays): CV%<10%; 1: Three samples of known concentration were tested in twenty assays to assess.; |
| Linearity | headers: To assess the linearity of the assay, samples were spiked with high concentrations of mouse E-Selectin in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; rows: To assess the linearity of the assay, samples were spiked with high concentrations of mouse E-Selectin in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.: To assess the linearity of the assay, samples were spiked with high concentrations of mouse E-Selectin in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; 2: Sample; 3: Serum(n=4); 1: 1:1; 2: Average %; 3: 93; 1: Range %; 2: 90-96; 1: 1:2; 2: Average %; 3: 85; 1: Range %; 2: 81-90; 1: 1:4; 2: Average %; 3: 104; 1: Range %; 2: 100-108; 1: 1:8; 2: Average %; 3: 86; 1: Range %; 2: 82-90 |
| Recovery | headers: The recovery of mouse E-Selectin spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; rows: The recovery of mouse E-Selectin spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.: The recovery of mouse E-Selectin spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; ; 1: Sample Type; 2: Average % Recovery; 3: Range; 1: Serum (n=5); 2: 102; 3: 98-106; 1: EDTA plasma (n=4); 2: 89; 3: 85-94; ; |
| Typical Data | headers: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; rows: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; ; 1: pg/ml OD1 OD2 Average Corrected 5000 2.076 2.131 2.104 1.907 2500 1.671 1.638 1.655 1.458 1250 1.168 1.201 1.185 0.988 625 0.829 0.831 0.830 0.633 312 0.505 0.511 0.508 0.311 156 0.365 0.372 0.369 0.172 78 0.285 0.289 0.287 0.090 0 0.195 0.199 0.197; 2: pg/ml; 3: OD1; 4: OD2; 5: Average; 6: Corrected; 9: 5000; 10: 2.076; 11: 2.131; 12: 2.104; 13: 1.907; 16: 2500; 17: 1.671; 18: 1.638; 19: 1.655; 20: 1.458; 23: 1250; 24: 1.168; 25: 1.201; 26: 1.185; 27: 0.988; 30: 625; 31: 0.829; 32: 0.831; 33: 0.830; 34: 0.633; 37: 312; 38: 0.505; 39: 0.511; 40: 0.508; 41: 0.311; 44: 156; 45: 0.365; 46: 0.372; 47: 0.369; 48: 0.172; 51: 78; 52: 0.285; 53: 0.289; 54: 0.287; 55: 0.090; 58: 0; 59: 0.195; 60: 0.199; 61: 0.197; 1: pg/ml; 2: OD1; 3: OD2; 4: Average; 5: Corrected; 1: 5000; 2: 2.076; 3: 2.131; 4: 2.104; 5: 1.907; 1: 2500; 2: 1.671; 3: 1.638; 4: 1.655; 5: 1.458; 1: 1250; 2: 1.168; 3: 1.201; 4: 1.185; 5: 0.988; 1: 625; 2: 0.829; 3: 0.831; 4: 0.830; 5: 0.633; 1: 312; 2: 0.505; 3: 0.511; 4: 0.508; 5: 0.311; 1: 156; 2: 0.365; 3: 0.372; 4: 0.369; 5: 0.172; 1: 78; 2: 0.285; 3: 0.289; 4: 0.287; 5: 0.090; 1: 0; 2: 0.195; 3: 0.199; 4: 0.197 |
| ELISA Data Analysis | ELISA Standard Curve & Curve Expert software |
| Shelf Life | 6 months |
| Description | This Mouse SELE ELISA Kit was designed for the quantitative measurement of Mouse SELE protein in serum, plasma, tissue homogenates. It is a Sandwich ELISA kit, its detection range is 78 pg/mL-5000 pg/mL and the sensitivity is 19.5 pg/mL. |
MDSD