Human Aminoacyl tRNA synthase complex-interacting multifunctional protein 1(SCYE1) ELISA kit CSB-EL020871HU CUSABIO

$50.00
In stock
SKU
CSB-EL020871HU

Product Details

Target Namesmall inducible cytokine subfamily E, member 1 (endothelial monocyte-activating)
Uniprot No.Q12904
SpeciesHomo sapiens (Human)
StorageStore at 2-8°C. Please refer to protocol.
Sensitivity5.8 pg/mL
Troubleshooting and FAQsELISA kit FAQs
Lead Time3-5 working days after you place the order, and it takes another 3-5 days for delivery via DHL or FedEx.
Associated namesAIMP 1 ELISA Kit; Aimp1 ELISA Kit; AIMP1/p43 ELISA Kit; AIMP1_HUMAN ELISA Kit; Aminoacyl tRNA synthetase complex-interacting multifunctional protein 1 ELISA Kit; ARS interacting multifunctional protein 1 ELISA Kit; EMAP 2 ELISA Kit; EMAP-2 ELISA Kit; EMAP-II ELISA Kit; EMAP2 ELISA Kit; EMAPII ELISA Kit; Endothelial monocyte activating polypeptide 2 ELISA Kit; Endothelial monocyte activating polypeptide ELISA Kit; Endothelial monocyte-activating polypeptide 2 ELISA Kit; Endothelial monocyte-activating polypeptide II ELISA Kit; HLD3 ELISA Kit; Multisynthase complex auxiliary component p43 ELISA Kit; Multisynthetase complex auxiliary component p43 ELISA Kit; OTTHUMP00000219673 ELISA Kit; p43 ELISA Kit; Scye 1 ELISA Kit; Scye1 ELISA Kit; Scye1, formerly ELISA Kit; Small inducible cytokine subfamily E member 1 ELISA Kit; Small inducible cytokine subfamily E, member 1 (endothelial monocyte-activating) ELISA Kit; Small inducible cytokine subfamily E, member 1, formerly ELISA Kit
AbbreviationSCYE1
Sample Typesserum, plasma, tissue homogenates, cell lysates
Detection Range23.5 pg/mL-1500 pg/mL
Assay Time1-5h
Sample Loading Volume50-100ul
Detection Wavelength450 nm
Research AreaOthers
Assay Principlequantitative
MeasurementSandwich
Precisionheaders: Intra-assay Precision (Precision within an assay): CV%<8%; rows: Intra-assay Precision (Precision within an assay): CV%<8%: Intra-assay Precision (Precision within an assay): CV%<8%; 1: Three samples of known concentration were tested twenty times on one plate to assess.; Intra-assay Precision (Precision within an assay): CV%<8%: Inter-assay Precision (Precision between assays): CV%<10%; 1: Three samples of known concentration were tested in twenty assays to assess.;
Linearityheaders: To assess the linearity of the assay, samples were spiked with high concentrations of human SCYE1 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; rows: To assess the linearity of the assay, samples were spiked with high concentrations of human SCYE1 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.: To assess the linearity of the assay, samples were spiked with high concentrations of human SCYE1 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; 2: Sample; 3: Serum(n=4); 1: 1:1; 2: Average %; 3: 102; 1: Range %; 2: 95-106; 1: 1:2; 2: Average %; 3: 101; 1: Range %; 2: 96-105; 1: 1:4; 2: Average %; 3: 89; 1: Range %; 2: 86-94; 1: 1:8; 2: Average %; 3: 94; 1: Range %; 2: 89-98
Recoveryheaders: The recovery of human SCYE1 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; rows: The recovery of human SCYE1 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.: The recovery of human SCYE1 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; ; 1: Sample Type; 2: Average % Recovery; 3: Range; 1: Serum (n=5); 2: 104; 3: 98-108; 1: EDTA plasma (n=4); 2: 93; 3: 86-97; ;
Typical Dataheaders: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; rows: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; ; 1: pg/ml OD1 OD2 Average Corrected 1500 1.976 1.933 1.955 1.800 750 1.365 1.284 1.325 1.170 375 0.872 0.828 0.850 0.695 187.5 0.578 0.545 0.562 0.407 94 0.388 0.361 0.375 0.220 47 0.251 0.246 0.249 0.094 23.5 0.219 0.215 0.217 0.062 0 0.156 0.154 0.155; 2: pg/ml; 3: OD1; 4: OD2; 5: Average; 6: Corrected; 9: 1500; 10: 1.976; 11: 1.933; 12: 1.955; 13: 1.800; 16: 750; 17: 1.365; 18: 1.284; 19: 1.325; 20: 1.170; 23: 375; 24: 0.872; 25: 0.828; 26: 0.850; 27: 0.695; 30: 187.5; 31: 0.578; 32: 0.545; 33: 0.562; 34: 0.407; 37: 94; 38: 0.388; 39: 0.361; 40: 0.375; 41: 0.220; 44: 47; 45: 0.251; 46: 0.246; 47: 0.249; 48: 0.094; 51: 23.5; 52: 0.219; 53: 0.215; 54: 0.217; 55: 0.062; 58: 0; 59: 0.156; 60: 0.154; 61: 0.155; 1: pg/ml; 2: OD1; 3: OD2; 4: Average; 5: Corrected; 1: 1500; 2: 1.976; 3: 1.933; 4: 1.955; 5: 1.800; 1: 750; 2: 1.365; 3: 1.284; 4: 1.325; 5: 1.170; 1: 375; 2: 0.872; 3: 0.828; 4: 0.850; 5: 0.695; 1: 187.5; 2: 0.578; 3: 0.545; 4: 0.562; 5: 0.407; 1: 94; 2: 0.388; 3: 0.361; 4: 0.375; 5: 0.220; 1: 47; 2: 0.251; 3: 0.246; 4: 0.249; 5: 0.094; 1: 23.5; 2: 0.219; 3: 0.215; 4: 0.217; 5: 0.062; 1: 0; 2: 0.156; 3: 0.154; 4: 0.155
ELISA Data AnalysisELISA Standard Curve & Curve Expert software
Shelf Life6 months
DescriptionThis Human SCYE1 ELISA Kit was designed for the quantitative measurement of Human SCYE1 protein in serum, plasma, tissue homogenates, cell lysates. It is a Sandwich ELISA kit, its detection range is 23.5 pg/mL-1500 pg/mL and the sensitivity is 5.8 pg/mL.

MDSD

MSDS

Reviews

Write Your Own Review
You're reviewing:Human Aminoacyl tRNA synthase complex-interacting multifunctional protein 1(SCYE1) ELISA kit CSB-EL020871HU CUSABIO
Your Rating
Copyright © 2025 Biogege, Inc. All rights reserved.