Human Bcl-2-like protein 11(BCL2L11) ELISA kit CSB-EL002615HU CUSABIO
$50.00
In stock
SKU
CSB-EL002615HU
Product Details
| Target Name | BCL2-like 11 (apoptosis facilitator) |
| Uniprot No. | O43521 |
| Species | Homo sapiens (Human) |
| Storage | Store at 2-8°C. Please refer to protocol. |
| Sensitivity | 5.86 pg/mL |
| Troubleshooting and FAQs | ELISA kit FAQs |
| Lead Time | 3-5 working days after you place the order, and it takes another 3-5 days for delivery via DHL or FedEx. |
| Associated names | BCL2 like 11 ELISA Kit; B2L11_HUMAN ELISA Kit; BAM ELISA Kit; Bcl 2 interacting protein Bim ELISA Kit; Bcl 2 related ovarian death agonist ELISA Kit; Bcl-2-like protein 11 ELISA Kit; BCL2 interacting mediator of cell death ELISA Kit; BCL2 like 11 (apoptosis facilitator) ELISA Kit; BCL2 like protein 11 ELISA Kit; Bcl2-interacting mediator of cell death ELISA Kit; Bcl2-L-11 ELISA Kit; Bcl2l11 ELISA Kit; BIM alpha6 ELISA Kit; BIM ELISA Kit; BIM beta6 ELISA Kit; BIM beta7 ELISA Kit; BimEL ELISA Kit; BimL ELISA Kit; BOD ELISA Kit |
| Abbreviation | BCL2L11 |
| Sample Types | serum, plasma, tissue homogenates, cell lysates |
| Detection Range | 23.44 pg/mL-1500 pg/mL |
| Assay Time | 1-5h |
| Sample Loading Volume | 50-100ul |
| Detection Wavelength | 450 nm |
| Research Area | Cell Biology |
| Assay Principle | quantitative |
| Measurement | Sandwich |
| Precision | headers: Intra-assay Precision (Precision within an assay): CV%<8%; rows: Intra-assay Precision (Precision within an assay): CV%<8%: Intra-assay Precision (Precision within an assay): CV%<8%; 1: Three samples of known concentration were tested twenty times on one plate to assess.; Intra-assay Precision (Precision within an assay): CV%<8%: Inter-assay Precision (Precision between assays): CV%<10%; 1: Three samples of known concentration were tested in twenty assays to assess.; |
| Linearity | headers: To assess the linearity of the assay, samples were spiked with high concentrations of human BCL2L11 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; rows: To assess the linearity of the assay, samples were spiked with high concentrations of human BCL2L11 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.: To assess the linearity of the assay, samples were spiked with high concentrations of human BCL2L11 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; 2: Sample; 3: Serum(n=4); 1: 1:1; 2: Average %; 3: 96; 1: Range %; 2: 90-102; 1: 1:2; 2: Average %; 3: 92; 1: Range %; 2: 84-97; 1: 1:4; 2: Average %; 3: 99; 1: Range %; 2: 95-105; 1: 1:8; 2: Average %; 3: 97; 1: Range %; 2: 92-104 |
| Recovery | headers: The recovery of human BCL2L11 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; rows: The recovery of human BCL2L11 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.: The recovery of human BCL2L11 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; 1: Sample Type; 2: Average % Recovery; 3: Range; 1: Serum (n=5); 2: 96; 3: 90-102; 1: EDTA plasma (n=4); 2: 102; 3: 98-108; ; |
| Typical Data | headers: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; rows: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; 1: pg/ml OD1 OD2 Average Corrected 1500 2.194 2.187 2.191 1.991 750 1.506 1.537 1.522 1.322 375 1.012 1.036 1.024 0.824 187.5 0.659 0.689 0.674 0.474 93.75 0.445 0.426 0.436 0.236 46.88 0.345 0.324 0.335 0.135 23.44 0.260 0.282 0.271 0.071 0 0.201 0.198 0.200; 2: pg/ml; 3: OD1; 4: OD2; 5: Average; 6: Corrected; 8: 1500; 9: 2.194; 10: 2.187; 11: 2.191; 12: 1.991; 14: 750; 15: 1.506; 16: 1.537; 17: 1.522; 18: 1.322; 20: 375; 21: 1.012; 22: 1.036; 23: 1.024; 24: 0.824; 26: 187.5; 27: 0.659; 28: 0.689; 29: 0.674; 30: 0.474; 32: 93.75; 33: 0.445; 34: 0.426; 35: 0.436; 36: 0.236; 38: 46.88; 39: 0.345; 40: 0.324; 41: 0.335; 42: 0.135; 44: 23.44; 45: 0.260; 46: 0.282; 47: 0.271; 48: 0.071; 50: 0; 51: 0.201; 52: 0.198; 53: 0.200; 1: pg/ml; 2: OD1; 3: OD2; 4: Average; 5: Corrected; 1: 1500; 2: 2.194; 3: 2.187; 4: 2.191; 5: 1.991; 1: 750; 2: 1.506; 3: 1.537; 4: 1.522; 5: 1.322; 1: 375; 2: 1.012; 3: 1.036; 4: 1.024; 5: 0.824; 1: 187.5; 2: 0.659; 3: 0.689; 4: 0.674; 5: 0.474; 1: 93.75; 2: 0.445; 3: 0.426; 4: 0.436; 5: 0.236; 1: 46.88; 2: 0.345; 3: 0.324; 4: 0.335; 5: 0.135; 1: 23.44; 2: 0.260; 3: 0.282; 4: 0.271; 5: 0.071; 1: 0; 2: 0.201; 3: 0.198; 4: 0.200 |
| ELISA Data Analysis | ELISA Standard Curve & Curve Expert software |
| Shelf Life | 6 months |
| Description | This Human BCL2L11 ELISA Kit was designed for the quantitative measurement of Human BCL2L11 protein in serum, plasma, tissue homogenates, cell lysates. It is a Sandwich ELISA kit, its detection range is 23.44 pg/mL-1500 pg/mL and the sensitivity is 5.86 pg/mL . |
MDSD