Human Bcl-2-related protein A1(BCL2A1) ELISA kit CSB-EL002612HU CUSABIO
$50.00
In stock
SKU
CSB-EL002612HU
Product Details
| Target Name | BCL2-related protein A1 |
| Uniprot No. | Q16548 |
| Species | Homo sapiens (Human) |
| Storage | Store at 2-8°C. Please refer to protocol. |
| Sensitivity | 7.81 pg/mL |
| Troubleshooting and FAQs | ELISA kit FAQs |
| Lead Time | 3-5 working days after you place the order, and it takes another 3-5 days for delivery via DHL or FedEx. |
| Associated names | ACC 1 ELISA Kit; ACC 2 ELISA Kit; B2LA1_HUMAN ELISA Kit; Bcl 2 related protein A1 ELISA Kit; Bcl-2-like protein 5 ELISA Kit; Bcl-2-related protein A1 ELISA Kit; BCL2 related protein A1 ELISA Kit; Bcl2-L-5 ELISA Kit; BCL2A1 ELISA Kit; BCL2L5 ELISA Kit; BFL1 ELISA Kit; GRS ELISA Kit; HBPA1 ELISA Kit; Hematopoietic BCL2 related protein A1 ELISA Kit; Hemopoietic specific early response protein ELISA Kit; Hemopoietic-specific early response protein ELISA Kit; Protein BFL 1 ELISA Kit; Protein BFL-1 ELISA Kit; Protein GRS ELISA Kit |
| Abbreviation | BCL2A1 |
| Sample Types | serum, plasma, tissue homogenates, cell lysates |
| Detection Range | 31.25 pg/mL-2000 pg/mL |
| Assay Time | 1-5h |
| Sample Loading Volume | 50-100ul |
| Detection Wavelength | 450 nm |
| Research Area | Cell Biology |
| Assay Principle | quantitative |
| Measurement | Sandwich |
| Precision | headers: Intra-assay Precision (Precision within an assay): CV%<8%; rows: Intra-assay Precision (Precision within an assay): CV%<8%: Intra-assay Precision (Precision within an assay): CV%<8%; 1: Three samples of known concentration were tested twenty times on one plate to assess.; Intra-assay Precision (Precision within an assay): CV%<8%: Inter-assay Precision (Precision between assays): CV%<10%; 1: Three samples of known concentration were tested in twenty assays to assess.; |
| Linearity | headers: To assess the linearity of the assay, samples were spiked with high concentrations of human BCL2A1 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; rows: To assess the linearity of the assay, samples were spiked with high concentrations of human BCL2A1 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.: To assess the linearity of the assay, samples were spiked with high concentrations of human BCL2A1 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; 2: Sample; 3: Serum(n=4); 1: 1:1; 2: Average %; 3: 86; 1: Range %; 2: 80-94; 1: 1:2; 2: Average %; 3: 97; 1: Range %; 2: 91-100; 1: 1:4; 2: Average %; 3: 96; 1: Range %; 2: 92-101; 1: 1:8; 2: Average %; 3: 94; 1: Range %; 2: 89-98 |
| Recovery | headers: The recovery of human BCL2A1 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; rows: The recovery of human BCL2A1 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.: The recovery of human BCL2A1 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; 1: Sample Type; 2: Average % Recovery; 3: Range; 1: Serum (n=5); 2: 95; 3: 90-98; 1: EDTA plasma (n=4); 2: 97; 3: 92-100; ; |
| Typical Data | headers: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; rows: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; 1: pg/ml OD1 OD2 Average Corrected 2000 2.118 1.952 2.035 1.845 1000 1.426 1.338 1.382 1.192 500 0.894 0.854 0.874 0.684 250 0.592 0.581 0.587 0.397 125 0.455 0.438 0.447 0.257 62.5 0.373 0.365 0.369 0.179 31.25 0.253 0.250 0.252 0.062 0 0.190 0.189 0.190; 2: pg/ml; 3: OD1; 4: OD2; 5: Average; 6: Corrected; 8: 2000; 9: 2.118; 10: 1.952; 11: 2.035; 12: 1.845; 14: 1000; 15: 1.426; 16: 1.338; 17: 1.382; 18: 1.192; 20: 500; 21: 0.894; 22: 0.854; 23: 0.874; 24: 0.684; 26: 250; 27: 0.592; 28: 0.581; 29: 0.587; 30: 0.397; 32: 125; 33: 0.455; 34: 0.438; 35: 0.447; 36: 0.257; 38: 62.5; 39: 0.373; 40: 0.365; 41: 0.369; 42: 0.179; 44: 31.25; 45: 0.253; 46: 0.250; 47: 0.252; 48: 0.062; 50: 0; 51: 0.190; 52: 0.189; 53: 0.190; 1: pg/ml; 2: OD1; 3: OD2; 4: Average; 5: Corrected; 1: 2000; 2: 2.118; 3: 1.952; 4: 2.035; 5: 1.845; 1: 1000; 2: 1.426; 3: 1.338; 4: 1.382; 5: 1.192; 1: 500; 2: 0.894; 3: 0.854; 4: 0.874; 5: 0.684; 1: 250; 2: 0.592; 3: 0.581; 4: 0.587; 5: 0.397; 1: 125; 2: 0.455; 3: 0.438; 4: 0.447; 5: 0.257; 1: 62.5; 2: 0.373; 3: 0.365; 4: 0.369; 5: 0.179; 1: 31.25; 2: 0.253; 3: 0.250; 4: 0.252; 5: 0.062; 1: 0; 2: 0.190; 3: 0.189; 4: 0.190 |
| ELISA Data Analysis | ELISA Standard Curve & Curve Expert software |
| Shelf Life | 6 months |
| Description | This Human BCL2A1 ELISA Kit was designed for the quantitative measurement of Human BCL2A1 protein in serum, plasma, tissue homogenates, cell lysates. It is a Sandwich ELISA kit, its detection range is 31.25 pg/mL-2000 pg/mL and the sensitivity is 7.81 pg/mL. |