Human C-C motif chemokine 5 (CCL5/D17S136E/SCYA5) ELISA kit CSB-E17375h CUSABIO
$50.00
In stock
SKU
CSB-E17375h
Product Details
| Target Name | chemokine (C-C motif) ligand 5 |
| Uniprot No. | P13501 |
| Species | Homo sapiens (Human) |
| Storage | Store at 2-8°C. Please refer to protocol. |
| Sensitivity | 2.307 pg/mL |
| Troubleshooting and FAQs | ELISA kit FAQs |
| Lead Time | 3-5 working days after you place the order, and it takes another 3-5 days for delivery via DHL or FedEx. |
| Associated names | Beta chemokine RANTES ELISA Kit; Beta chemokine RANTES precursor ELISA Kit; C C motif chemokine 5 ELISA Kit; CCL 5 ELISA Kit; CCL5 ELISA Kit; CCL5_HUMAN ELISA Kit; Chemokine (C C motif) ligand 5 ELISA Kit; Chemokine CC Motif Ligand 5 ELISA Kit; D17S136E ELISA Kit; EoCP ELISA Kit; Eosinophil chemotactic cytokine ELISA Kit; MGC17164 ELISA Kit; RANTES(4-68) ELISA Kit; Regulated upon activation normally T expressed and presumably secreted ELISA Kit; SCYA 5 ELISA Kit; SCYA5 ELISA Kit; SIS delta ELISA Kit; SIS-delta ELISA Kit; SISd ELISA Kit; Small inducible cytokine A5 (RANTES) ELISA Kit; Small inducible cytokine A5 ELISA Kit; Small inducible cytokine subfamily A (Cys Cys) member 5 ELISA Kit; Small-inducible cytokine A5 ELISA Kit; T cell specific protein p288 ELISA Kit; T cell specific protein RANTES ELISA Kit; T cell specific RANTES protein ELISA Kit; T cell-specific protein P228 ELISA Kit; T-cell-specific protein RANTES ELISA Kit; TCP 228 ELISA Kit; TCP228 ELISA Kit |
| Abbreviation | CCL5 |
| Sample Types | serum, plasma, cell culture supernates, tissue homogenates |
| Detection Range | 15.6 pg/mL-1000 pg/mL |
| Assay Time | 1-5h |
| Sample Loading Volume | 50-100ul |
| Detection Wavelength | 450 nm |
| Research Area | Immunology |
| Assay Principle | quantitative |
| Measurement | Sandwich |
| Precision | headers: Intra-assay Precision (Precision within an assay): CV%<8%; rows: Intra-assay Precision (Precision within an assay): CV%<8%: Intra-assay Precision (Precision within an assay): CV%<8%; 1: Three samples of known concentration were tested twenty times on one plate to assess.; Intra-assay Precision (Precision within an assay): CV%<8%: Inter-assay Precision (Precision between assays): CV%<10%; 1: Three samples of known concentration were tested in twenty assays to assess.; |
| Linearity | headers: To assess the linearity of the assay, samples were spiked with high concentrations of human CCL5 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; rows: To assess the linearity of the assay, samples were spiked with high concentrations of human CCL5 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.: To assess the linearity of the assay, samples were spiked with high concentrations of human CCL5 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; 2: Sample; 3: Serum(n=4); 1: 1:100; 2: Average %; 3: 92; 1: Range %; 2: 87-95; 1: 1:200; 2: Average %; 3: 104; 1: Range %; 2: 96-107; 1: 1:400; 2: Average %; 3: 93; 1: Range %; 2: 88-97; 1: 1:800; 2: Average %; 3: 99; 1: Range %; 2: 94-103 |
| Recovery | headers: The recovery of human CCL5 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; rows: The recovery of human CCL5 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.: The recovery of human CCL5 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; 1: Sample Type; 2: Average % Recovery; 3: Range; 1: Serum (n=5); 2: 94; 3: 86-98; 1: EDTA plasma (n=4); 2: 99; 3: 92-104; ; |
| Typical Data | headers: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; rows: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; 1: pg/ml OD1 OD2 Average Corrected 1000 2.671 2.542 2.607 2.511 500 1.848 1.776 1.812 1.716 250 1.026 1.007 1.017 0.921 125 0.575 0.583 0.579 0.483 62.5 0.332 0.344 0.338 0.242 31.2 0.258 0.247 0.253 0.157 15.6 0.160 0.172 0.166 0.070 0 0.098 0.094 0.096; 2: pg/ml; 3: OD1; 4: OD2; 5: Average; 6: Corrected; 8: 1000; 9: 2.671; 10: 2.542; 11: 2.607; 12: 2.511; 14: 500; 15: 1.848; 16: 1.776; 17: 1.812; 18: 1.716; 20: 250; 21: 1.026; 22: 1.007; 23: 1.017; 24: 0.921; 26: 125; 27: 0.575; 28: 0.583; 29: 0.579; 30: 0.483; 32: 62.5; 33: 0.332; 34: 0.344; 35: 0.338; 36: 0.242; 38: 31.2; 39: 0.258; 40: 0.247; 41: 0.253; 42: 0.157; 44: 15.6; 45: 0.160; 46: 0.172; 47: 0.166; 48: 0.070; 50: 0; 51: 0.098; 52: 0.094; 53: 0.096; 1: pg/ml; 2: OD1; 3: OD2; 4: Average; 5: Corrected; 1: 1000; 2: 2.671; 3: 2.542; 4: 2.607; 5: 2.511; 1: 500; 2: 1.848; 3: 1.776; 4: 1.812; 5: 1.716; 1: 250; 2: 1.026; 3: 1.007; 4: 1.017; 5: 0.921; 1: 125; 2: 0.575; 3: 0.583; 4: 0.579; 5: 0.483; 1: 62.5; 2: 0.332; 3: 0.344; 4: 0.338; 5: 0.242; 1: 31.2; 2: 0.258; 3: 0.247; 4: 0.253; 5: 0.157; 1: 15.6; 2: 0.160; 3: 0.172; 4: 0.166; 5: 0.070; 1: 0; 2: 0.098; 3: 0.094; 4: 0.096 |
| ELISA Data Analysis | ELISA Standard Curve & Curve Expert software |
| Shelf Life | 6 months |
| Description | This Human CCL5 ELISA Kit was designed for the quantitative measurement of Human CCL5 protein in serum, plasma, cell culture supernates, tissue homogenates. It is a Sandwich ELISA kit, its detection range is 15.6 pg/mL-1000 pg/mL and the sensitivity is 2.307 pg/mL. |
MDSD