Human Complement factor H-related protein 2(CFHR2) ELISA kit CSB-EL005275HU CUSABIO
$50.00
In stock
SKU
CSB-EL005275HU
Product Details
| Target Name | complement factor H-related 2 |
| Uniprot No. | P36980 |
| Species | Homo sapiens (Human) |
| Storage | Store at 2-8°C. Please refer to protocol. |
| Sensitivity | 1.56 ng/mL |
| Troubleshooting and FAQs | ELISA kit FAQs |
| Lead Time | 3-5 working days after you place the order, and it takes another 3-5 days for delivery via DHL or FedEx. |
| Associated names | CFHL2 ELISA Kit; CFHR2 ELISA Kit; Complement factor H related protein 2 ELISA Kit; Complement factor H-related 2 ELISA Kit; Complement factor H-related protein 2 ELISA Kit; DDESK59 ELISA Kit; Factor H-related gene 2 ELISA Kit; FHR 2 ELISA Kit; FHR-2 ELISA Kit; FHR2 ELISA Kit; FHR2_HUMAN ELISA Kit; H factor (complement)-like 3 ELISA Kit; H factor like 3 ELISA Kit; H factor like protein 2 ELISA Kit; H factor-like 3 ELISA Kit; H factor-like protein 2 ELISA Kit; HFL3 ELISA Kit |
| Abbreviation | CFHR2 |
| Sample Types | serum, plasma, tissue homogenates |
| Detection Range | 6.25 ng/mL-400 ng/mL |
| Assay Time | 1-5h |
| Sample Loading Volume | 50-100ul |
| Detection Wavelength | 450 nm |
| Research Area | Immunology |
| Assay Principle | quantitative |
| Measurement | Sandwich |
| Precision | headers: Intra-assay Precision (Precision within an assay): CV%<8%; rows: Intra-assay Precision (Precision within an assay): CV%<8%: Intra-assay Precision (Precision within an assay): CV%<8%; 1: Three samples of known concentration were tested twenty times on one plate to assess.; Intra-assay Precision (Precision within an assay): CV%<8%: Inter-assay Precision (Precision between assays): CV%<10%; 1: Three samples of known concentration were tested in twenty assays to assess.; |
| Linearity | headers: To assess the linearity of the assay, samples were spiked with high concentrations of human CFHR2 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; rows: To assess the linearity of the assay, samples were spiked with high concentrations of human CFHR2 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.: To assess the linearity of the assay, samples were spiked with high concentrations of human CFHR2 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; 2: Sample; 3: Serum(n=4); 1: 1:100; 2: Average %; 3: 91; 1: Range %; 2: 87-95; 1: 1:200; 2: Average %; 3: 96; 1: Range %; 2: 90-102; 1: 1:400; 2: Average %; 3: 104; 1: Range %; 2: 98-109; 1: 1:800; 2: Average %; 3: 92; 1: Range %; 2: 86-98 |
| Recovery | headers: The recovery of human CFHR2 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; rows: The recovery of human CFHR2 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.: The recovery of human CFHR2 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; ; 1: Sample Type; 2: Average % Recovery; 3: Range; 1: Serum (n=5); 2: 101; 3: 97-105; 1: EDTA plasma (n=4); 2: 94; 3: 87-98; ; |
| Typical Data | headers: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; rows: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; ; 1: ng/ml OD1 OD2 Average Corrected 400 2.520 2.637 2.579 2.485 200 2.124 2.205 2.165 2.071 100 1.446 1.557 1.502 1.408 50 0.937 0.923 0.930 0.836 25 0.458 0.461 0.460 0.366 12.5 0.271 0.283 0.277 0.183 6.25 0.156 0.163 0.160 0.066 0 0.093 0.095 0.094; 2: ng/ml; 3: OD1; 4: OD2; 5: Average; 6: Corrected; 9: 400; 10: 2.520; 11: 2.637; 12: 2.579; 13: 2.485; 16: 200; 17: 2.124; 18: 2.205; 19: 2.165; 20: 2.071; 23: 100; 24: 1.446; 25: 1.557; 26: 1.502; 27: 1.408; 30: 50; 31: 0.937; 32: 0.923; 33: 0.930; 34: 0.836; 37: 25; 38: 0.458; 39: 0.461; 40: 0.460; 41: 0.366; 44: 12.5; 45: 0.271; 46: 0.283; 47: 0.277; 48: 0.183; 51: 6.25; 52: 0.156; 53: 0.163; 54: 0.160; 55: 0.066; 58: 0; 59: 0.093; 60: 0.095; 61: 0.094; 1: ng/ml; 2: OD1; 3: OD2; 4: Average; 5: Corrected; 1: 400; 2: 2.520; 3: 2.637; 4: 2.579; 5: 2.485; 1: 200; 2: 2.124; 3: 2.205; 4: 2.165; 5: 2.071; 1: 100; 2: 1.446; 3: 1.557; 4: 1.502; 5: 1.408; 1: 50; 2: 0.937; 3: 0.923; 4: 0.930; 5: 0.836; 1: 25; 2: 0.458; 3: 0.461; 4: 0.460; 5: 0.366; 1: 12.5; 2: 0.271; 3: 0.283; 4: 0.277; 5: 0.183; 1: 6.25; 2: 0.156; 3: 0.163; 4: 0.160; 5: 0.066; 1: 0; 2: 0.093; 3: 0.095; 4: 0.094 |
| ELISA Data Analysis | ELISA Standard Curve & Curve Expert software |
| Shelf Life | 6 months |
| Description | This Human CFHR2 ELISA Kit was designed for the quantitative measurement of Human CFHR2 protein in serum, plasma, tissue homogenates. It is a Sandwich ELISA kit, its detection range is 6.25 ng/mL-400 ng/mL and the sensitivity is 1.56 ng/mL. |
MDSD