Human Fibrinogen-like protein 1(FGL1) ELISA kit CSB-EL008653HU CUSABIO
$50.00
In stock
SKU
CSB-EL008653HU
Product Details
| Uniprot No. | Q08830 |
| Species | Homo sapiens (Human) |
| Storage | Store at 2-8°C. Please refer to protocol. |
| Sensitivity | 0.039 ng/ml |
| Troubleshooting and FAQs | ELISA kit FAQs |
| Lead Time | 3-5 working days after you place the order, and it takes another 3-5 days for delivery via DHL or FedEx. |
| Associated names | FGL 1 ELISA Kit; Fgl1 ELISA Kit; FGL1_HUMAN ELISA Kit; Fibrinogen like 1 ELISA Kit; Fibrinogen like protein 1 ELISA Kit; Fibrinogen related protein 1 ELISA Kit; Fibrinogen-like protein 1 ELISA Kit; Hepassocin ELISA Kit; Hepatocellular carcinoma related sequence ELISA Kit; Hepatocyte derived fibrinogen related protein 1 ELISA Kit; Hepatocyte-derived fibrinogen-related protein 1 ELISA Kit; HFREP 1 ELISA Kit; HFREP-1 ELISA Kit; HFREP1 ELISA Kit; HP 041 ELISA Kit; HP-041 ELISA Kit; HP041 ELISA Kit; LFIRE 1 ELISA Kit; LFIRE-1 ELISA Kit; LFIRE1 ELISA Kit; Liver fibrinogen related protein 1 ELISA Kit; Liver fibrinogen-related protein 1 ELISA Kit; MFIRE 1 ELISA Kit; MGC108569 ELISA Kit; MGC12455 ELISA Kit; MGC37822 ELISA Kit; OTTHUMP00000122468 ELISA Kit |
| Abbreviation | FGL1 |
| Sample Types | serum, plasma, tissue homogenates |
| Detection Range | 0.156 ng/ml-10 ng/ml. |
| Assay Time | 1-5h |
| Sample Loading Volume | 50-100ul |
| Detection Wavelength | 450 nm |
| Research Area | Cardiovascular |
| Assay Principle | quantitative |
| Measurement | Sandwich |
| Precision | headers: Intra-assay Precision (Precision within an assay): CV%<8%; rows: Intra-assay Precision (Precision within an assay): CV%<8%: Intra-assay Precision (Precision within an assay): CV%<8%; 1: Three samples of known concentration were tested twenty times on one plate to assess.; Intra-assay Precision (Precision within an assay): CV%<8%: Inter-assay Precision (Precision between assays): CV%<10%; 1: Three samples of known concentration were tested in twenty assays to assess. |
| Linearity | headers: To assess the linearity of the assay, samples were spiked with high concentrations of Human FGL1 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; rows: To assess the linearity of the assay, samples were spiked with high concentrations of Human FGL1 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.: To assess the linearity of the assay, samples were spiked with high concentrations of Human FGL1 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.; 2: Sample; 3: Serum(n=4); 1: 1:1; 2: Average %; 3: 89; 1: Range %; 2: 84-94; 1: 1:2; 2: Average %; 3: 87; 1: Range %; 2: 82-93; 1: 1:4; 2: Average %; 3: 95; 1: Range %; 2: 89-99; 1: 1:8; 2: Average %; 3: 98; 1: Range %; 2: 92-104 |
| Recovery | headers: The recovery of Human FGL1 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; rows: The recovery of Human FGL1 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.: The recovery of Human FGL1 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.; 1: Sample Type; 2: Average % Recovery; 3: Range; 1: Serum (n=5); 2: 93; 3: 88-97; 1: EDTA plasma (n=4); 2: 87; 3: 82-92 |
| Typical Data | headers: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; rows: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.: These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.; ; ; 1: ng/ml; 2: OD1; 3: OD2; 4: Average; 5: Corrected; 1: 10; 2: 2.758; 3: 2.645; 4: 2.702; 5: 2.607; 1: 5; 2: 2.107; 3: 2.256; 4: 2.182; 5: 2.087; 1: 2.5; 2: 1.601; 3: 1.524; 4: 1.563; 5: 1.468; 1: 1.25; 2: 0.867; 3: 0.845; 4: 0.856; 5: 0.761; 1: 0.625; 2: 0.475; 3: 0.483; 4: 0.479; 5: 0.384; 1: 0.312; 2: 0.317; 3: 0.304; 4: 0.311; 5: 0.216; 1: 0.156; 2: 0.181; 3: 0.176; 4: 0.179; 5: 0.084; 1: 0; 2: 0.095; 3: 0.094; 4: 0.095 |
| Materials provided | A micro ELISA plate --- The 96-well plate has been pre-coated with an anti-human FGL1 antibody. This dismountable microplate can be divided into 12 x 8 strip plates. Two vials lyophilized standard ---Dilute a bottle of the standard at dilution series, read the OD values, and then draw a standard curve. One vial Biotin-labeled FGL1 antibody (100 x concentrate) (120 μl/bottle) ---Act as the detection antibody. One vial HRP-avidin (100 x concentrate) (120 μl/bottle) ---Bind to the detection antibody and react with the TMB substrate to make the solution chromogenic. One vial Biotin-antibodyDiluent (15 ml/bottle) ---Dilute the Biotin-antibody. One vial HRP-avidin Diluent (15 ml/bottle) ---Dilute the HRP-avidin solution. One vial Sample Diluent (50 ml/bottle)---Dilute the sample to an appropriate concentration. One vial Wash Buffer (25 x concentrate) (20 ml/bottle) ---Wash away unbound or free substances. One vial TMB Substrate (10 ml/bottle) ---Act as the chromogenic agent. TMB interacts with HRP, eliciting the solution turns blue. One vial Stop Solution (10 ml/bottle) ---Stop the color reaction. The solution color immediately turns from blue to yellow. Four Adhesive Strips (For 96 wells) --- Cover the microplate when incubation. An instruction manual |
| Materials not provided | A microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 540 nm or 570 nm. An incubator can provide stable incubation conditions up to 37°C±5°C. Centrifuge Vortex Squirt bottle, manifold dispenser, or automated microplate washer Absorbent paper for blotting the microtiter plate 50-300ul multi-channel micropipette Pipette tips Single-channel micropipette with different ranges 100ml and 500ml graduated cylinders Deionized or distilled water Timer Test tubes for dilution |
| ELISA Data Analysis | ELISA Standard Curve & Curve Expert software |
| Shelf Life | 6 months |
| Description | The Human Fibrinogen-like protein 1 (FGL1) ELISA Kit quantifies FGL1 in human serum, plasma, or tissue homogenates. It is not intended for diagnostic use. This assay kit was designed and optimized for cardiovascular research use in humans. The kit has undergone rigorous quality control in multiple parameters, including sensitivity, specificity, precision, linearity, recovery, and inter-batch difference. Refer to the product instructions for more details. This assay employs the quantitative sandwich enzyme immunoassay technique, in which FGL1 in the samples or standards are sandwiched between pre-coated FGL1 antibody and Biotin-conjugated FGL1 antibody. HRP-avidin is then added into the wells. Following a wash to remove any unbound reagent, the TMB substrate solution is added to the wells and color develops in proportion to the amount of FGL1 bound in the initial step. The color development is stopped upon adding the stop solution, and the intensity of the color is measured at 450 nm via a microplate reader. The levels of FGL1 in the samples can be determined by referring to the O.D. (optical density) of the samples to the standard curve. FGL1, also known as FREP1 or hepassocin, is a novel hepatocyte belonging to the fibrinogen family. It plays an important role in hepatic steatosis, insulin resistance, liver regeneration, and liver protection. FGL1 is normally released by the liver in low levels but by cancer in high levels. FGL1 acts as a major ligand of LAG-3 (Lymphocyte-activation gene 3) that mediates T cell inhibition, so blockade of the FGL1-LAG-3 interaction enhances antitumor immunity. |
MDSD