| Product name | Human SMARCC1 ELISA Kit |
| Synonyms | BAF155, BRG1-associated factor 155, CRACC1, Rsc8, SRG3 |
| Reactivity | Human |
| Host / Isotype | United States |
| Tests | 1 X 96 well plate |
| Sample type | Cell lysate |
| Assay type | Sandwich |
| Sensitivity | 0.01 ng/mL |
| Range | 0.156-10 ng/mL |
| Tested applications | Sandwich ELISA |
| Gene ID (NCBI) | 6599 |
| Sample Type | Average Range |
| Cell lysate | 84% 73%-111% |
| Sample | n mean ( ng/mL ) SD CV% |
| 1 | 16 4.89 0.24 4.91 |
| 2 | 16 1.21 0.05 4.13 |
| 3 | 16 0.64 0.02 3.13 |
| Storage Instructions | All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. |
SMARCC1, also known as BAF155, is a core structural subunit of the SWI/SNF (or BAF) chromatin remodeling complex. As a key epigenetic regulatory protein, it utilizes the energy from ATP hydrolysis to alter chromatin structure, thereby precisely controlling the switch for gene transcription. This protein plays a fundamental role in maintaining cellular identity and determining cell fate, such as in stem cell pluripotency and differentiation. Due to the critical importance of its function, mutations or dysregulation of SMARCC1 are closely associated with various diseases. Particularly as a significant tumor suppressor, it is frequently mutated in multiple cancers, making it a major focus of research as a tumor biomarker and a potential therapeutic target. Properties Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. Synonyms BAF155, BRG1-associated factor 155, CRACC1, Rsc8, SRG3 FAQ 1、I have limited sample diluent. How should I handle samples requiring high dilution factors? Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows: Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample. Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample. Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample. If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.