| Product name | Mouse APOE ELISA Kit |
| Synonyms | Apoe,AI255918,apolipoprotein E |
| Reactivity | Mouse |
| Host / Isotype | United States |
| Tests | 1 X 96 well plate |
| Sample type | Serum, Plasma |
| Assay type | Sandwich |
| Sensitivity | 0.05 ng/mL |
| Range | 0.156-10 ng/mL |
| Tested applications | Sandwich ELISA |
| Gene ID (NCBI) | 11816 |
| Sample Type | Average Range |
| Mouse serum | 100% 94%-120% |
| Sample | n mean ( ng/mL ) SD CV% |
| 1 | 24 6.66 0.59 8.93 |
| 2 | 24 1.14 0.03 2.47 |
| 3 | 24 0.41 0.02 3.73 |
| Storage Instructions | All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. |
Apolipoprotein E (APOE) is a core component of plasma lipoproteins and is involved in a variety of biological processes, including plasma lipoprotein metabolism, intracellular cholesterol utilization, cell growth, immune regulation, and neuronal growth and repair.The ε4 allele of the APOE gene is the strongest genetic risk factor for late-onset Alzheimer's disease (AD). Mouse APOE, like ApoE4, contains equivalents of Arg-112 and Glu-255 but lacks the critical Arg-61 equivalent. APOE has heparin-binding activity and binds to heparan sulfate proteoglycans on the cell surface, a property that facilitates cellular capture and receptor-mediated uptake of APOE-containing lipoproteins. Properties Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. Synonyms Apoe,AI255918,apolipoprotein E FAQ 1、I have limited sample diluent. How should I handle samples requiring high dilution factors? Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows: Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample. Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample. Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample. If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.