| Product name | Mouse Galectin-3 ELISA Kit |
| Synonyms | Gal-3, Lgals3, 35 kDa lectin |
| Reactivity | Mouse |
| Host / Isotype | United States |
| Tests | 1 X 96 well plate |
| Sample type | Serum, Plasma, Cell lysate |
| Assay type | Sandwich |
| Sensitivity | 0.6 pg/mL |
| Range | 7.81-500 pg/mL |
| Tested applications | Sandwich ELISA |
| Gene ID (NCBI) | 16854 |
| Sample Type | Average Range |
| Mouse serum | 99% 89%-107% |
| Cell lysate | 107% 95%-114% |
| Sample | n mean ( pg/mL ) SD CV% |
| 1 | 16 302.1 15.3 5.1 |
| 2 | 16 68.8 3.5 5.1 |
| 3 | 16 35.9 1.2 3.3 |
| Storage Instructions | All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. |
Galectin-3 is a member of the galectin family of lectins that bind β-galactosides. It is crucial in various biological processes, including inflammation, fibrosis, cell adhesion, and immune response regulation. Galectin-3 is involved in regulating leukocyte activity, influencing both the activation of leukocytes and the induction of apoptosis in T lymphocytes. Additionally, soluble Galectin-3 (sGalectin-3) acts as an alarmin, orchestrating immune responses and promoting inflammation in conditions such as traumatic brain injury. Elevated levels of sGalectin-3 have been observed in patients with heart failure and other cardiovascular conditions, suggesting its potential as a diagnostic and prognostic biomarker. Properties Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. Synonyms Gal-3, Lgals3, 35 kDa lectin FAQ 1、I have limited sample diluent. How should I handle samples requiring high dilution factors? Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows: Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample. Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample. Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample. If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.