| Product name | Mouse Tie-2 ELISA Kit |
| Synonyms | Angiopoietin-1 receptor, CD202b, EC:2.7.10.1, Endothelial tyrosine kinase, HYK |
| Reactivity | Mouse |
| Host / Isotype | United States |
| Tests | 1 X 96 well plate |
| Sample type | Serum, Plasma, Cell culture supernatant, Cell lysate, Tissue lysate, Tissue homogenates |
| Assay type | Sandwich |
| Sensitivity | 7.6 pg/mL |
| Range | 46.88-3000 pg/mL |
| Tested applications | Sandwich ELISA |
| Gene ID (NCBI) | 21687 |
| Sample Type | Average Range |
| Mouse serum | 96% 90%-109% |
| Cell culture supernatant | 96% 94%-100% |
| Cell lysate | 101% 97%-108% |
| Tissue homogenates | 103% 93%-113% |
| Sample | n mean ( pg/mL ) SD CV% |
| 1 | 16 1,500.7 103.6 6.9 |
| 2 | 16 408.6 37.2 9.1 |
| 3 | 16 218.0 28.7 13.2 |
| Storage Instructions | All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. |
Tie-2 (also known as TEK or CD202b) is a receptor tyrosine kinase (RTK) critical for vascular development, angiogenesis, and endothelial cell function. Tie-2 is essential for blood vessel maturation. Genetic knockout of Tie-2 or Ang-1 in mice leads to embryonic lethality due to defects in cardiac development and vascular remodeling. Ligand-induced Tie-2 phosphorylation activates PI3K-AKT (promoting survival) and MAPK pathways (regulating proliferation and migration). Properties Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. Synonyms Angiopoietin-1 receptor, CD202b, EC:2.7.10.1, Endothelial tyrosine kinase, HYK FAQ 1、I have limited sample diluent. How should I handle samples requiring high dilution factors? Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows: Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample. Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample. Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample. If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.