| Product name | Human Alpha-1-Antitrypsin/SERPINA1 ELISA Kit |
| Synonyms | a1-antitrypsin,Alpha-1-antitrypsin,Serpin A1,SERPI |
| Reactivity | Human |
| Host / Isotype | United States |
| Tests | 1 X 96 well plate |
| Sample type | Milk, Serum, Plasma, Saliva, Urine |
| Assay type | Sandwich |
| Sensitivity | 0.04 ng/mL |
| Range | 0.39-25 ng/mL |
| Tested applications | Sandwich ELISA |
| Gene ID (NCBI) | 5265 |
| Sample Type | Average Range |
| Human plasma | 90% 77%-112% |
| Urine | 95% 83%-123% |
| Saliva | 96% 83%-115% |
| Milk | 86% 74%-97% |
| Sample | n mean ( ng/mL ) SD CV% |
| 1 | 24 11.15 0.52 4.64 |
| 2 | 24 2.68 0.11 4.21 |
| 3 | 24 0.67 0.04 6.02 |
| Storage Instructions | All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. |
Alpha-1-antitrypsin (AAT) is the gene for a protein called SERPINA1, which is a serine protease inhibitor whose targets include elastase, plasmin, thrombin, trypsin, chymotrypsin, and plasminogen activator. AAT is a glycoprotein synthesized primarily by hepatocytes, with smaller amountssynthesized by intestinal epithelial cells, neutrophils, pulmonary alveolar cells and macrophages. AAT is the most abundant, endogenous serine protease inhibitor in blood circulation and it has been implicated in regulating vital fluid phase biological events such as blood coagulation, fibrinolysis, complement activation, apoptosis, reproduction, tumor progression and inflammatory response. The primary function of AAT is thought to be the inactivation of neutrophil elastase and other endogenous serine proteases. Defects in SERPINA1 can cause emphysema or liver disease. Properties Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. Synonyms a1-antitrypsin,Alpha-1-antitrypsin,Serpin A1,SERPI FAQ 1、I have limited sample diluent. How should I handle samples requiring high dilution factors? Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows: Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample. Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample. Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample. If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.