| Product name | Human AES ELISA Kit |
| Synonyms | TLE5, AES 1, AES 2, Amino-terminal enhancer of split, ESP1 |
| Reactivity | Human |
| Host / Isotype | United States |
| Tests | 1 X 96 well plate |
| Sample type | Cell lysate |
| Assay type | Sandwich |
| Sensitivity | 0.06 ng/mL |
| Range | 0.313-20 ng/mL |
| Tested applications | Sandwich ELISA |
| Gene ID (NCBI) | 166 |
| Sample Type | Average Range |
| Cell lysate | 89% 70%-101% |
| Sample | n mean ( ng/mL ) SD CV% |
| 1 | 16 8.56 0.59 6.88 |
| 2 | 16 1.57 0.11 7.25 |
| 3 | 16 1.24 0.15 11.97 |
| Storage Instructions | All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. |
Amino-terminal enhancer of split (AES), also known as TLE5 or Grg5, belongs to the groucho/TLE family of proteins. AES can function as a homooligomer or as a heteroologimer with other family members in order to forcefully repress the expression of other family member genes. AES can repress NFkB-regulated gene expression and is believed to have a significant role in initiating and maintaining cell differentiation events. AES has been found to suppress local invasion and intravasation through inhibition of the Notch pathway, leading to preventing the metastatic spread of endogenous tumors, such as colon cancer and prostate cancer. Properties Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. Synonyms TLE5, AES 1, AES 2, Amino-terminal enhancer of split, ESP1 FAQ 1、I have limited sample diluent. How should I handle samples requiring high dilution factors? Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows: Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample. Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample. Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample. If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.