| Product name | Human AXL ELISA Kit |
| Synonyms | EC:2.7.10.1, Tyrosine-protein kinase receptor UFO, UFO |
| Reactivity | Human |
| Host / Isotype | United States |
| Tests | 1 X 96 well plate |
| Sample type | Serum, Plasma, Cell culture supernatant, Urine, Cell lysate, CSF |
| Assay type | Sandwich |
| Sensitivity | 7.6 pg/mL |
| Range | 31.25-2000 pg/mL |
| Tested applications | Sandwich ELISA |
| Gene ID (NCBI) | 558 |
| Sample Type | Average Range |
| Serum | 102% 89%-124% |
| Urine | 94% 83%-115% |
| Cell culture supernatant | 97% 88%-112% |
| Cell lysate | 95% 88%-105% |
| CSF | 90% 88%-92% |
| Sample | n mean ( pg/mL ) SD CV% |
| 1 | 16 972.4 51.7 5.3 |
| 2 | 16 238.5 17.3 7.3 |
| 3 | 16 120.5 10.4 8.6 |
| Storage Instructions | All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. |
Axl, also known as Ufo or Ark, is a receptor tyrosine kinase of the TAM (Tyro3, Axl, and Mer) family. Axl is a single-pass type I membrane protein containing two fibronectin type-III domains, two Ig-like C2-type domains, and one protein kinase domain. Axl mRNA is widely expressed with the highest levels in the heart and skeletal muscle. Gas6 has been identified as a ligand for human Axl. Gas6/Axl signaling plays a role in cell survival, cell proliferation, migration, and differentiation. Endogenous Axl is auto-phosphorylated and reacts with a tyrosine-phosphorylated protein of 140 kDa. Properties Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. Synonyms EC:2.7.10.1, Tyrosine-protein kinase receptor UFO, UFO FAQ 1、I have limited sample diluent. How should I handle samples requiring high dilution factors? Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows: Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample. Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample. Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample. If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.