| Product name | Human BMPR2 ELISA Kit |
| Synonyms | BMP type 2 receptor, BMP type II receptor, BMP type-2 receptor, BMPR 2, BMPR II |
| Reactivity | Human |
| Host / Isotype | United States |
| Tests | 1 X 96 well plate |
| Sample type | Cell lysate |
| Assay type | Sandwich |
| Sensitivity | 2.6 pg/mL |
| Range | 78.1-5000 pg/mL |
| Tested applications | Sandwich ELISA |
| Gene ID (NCBI) | 659 |
| Sample Type | Average Range |
| Cell lysate | 87% 87%-88% |
| Sample | n mean ( pg/mL ) SD CV% |
| 1 | 16 2,774.3 119.4 4.3 |
| 2 | 16 683.8 20.2 2.9 |
| 3 | 16 346.4 21.9 6.3 |
| Storage Instructions | All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. |
BMPR2 (bone morphogenetic protein receptor 2) is a member of the tumor growth factor-β receptor(TGF-βR) superfamily. BMP signaling through BMPR2 inhibits the proliferation and migration of smooth muscle and endothelial cells and prevents neointimal formation. Loss of function mutations of the Bone Morphogenetic Protein Receptor 2 (BMPR2) are the most common genetic factor in hereditary forms of PAH (Pulmonary Arterial Hypertension), suggesting that the BMPR2 pathway is fundamentally important in the pathogenesis. Moreover, the disruption of the BMPR2 signaling pathway causes an increased degree of inflammation and decreases the ability of the immune system to resolve it. Properties Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. Synonyms BMP type 2 receptor, BMP type II receptor, BMP type-2 receptor, BMPR 2, BMPR II FAQ 1、I have limited sample diluent. How should I handle samples requiring high dilution factors? Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows: Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample. Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample. Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample. If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.