| Product name | Human C5AR1/CD88 ELISA Kit |
| Synonyms | C5AR, C5AR1, C5A, C5a anaphylatoxin chemotactic receptor 1, C5a R |
| Reactivity | Human |
| Host / Isotype | United States |
| Tests | 1 X 96 well plate |
| Sample type | Cell lysate |
| Assay type | Sandwich |
| Sensitivity | 0.12 ng/mL |
| Range | 0.313-20 ng/mL |
| Tested applications | Sandwich ELISA |
| Gene ID (NCBI) | 728 |
| Sample Type | Average Range |
| Cell lysate | 100% 92%-115% |
| Sample | n mean ( ng/mL ) SD CV% |
| 1 | 16 10.09 0.89 8.82 |
| 2 | 16 2.34 0.20 8.60 |
| 3 | 16 1.25 0.08 6.23 |
| Storage Instructions | All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. |
C5a anaphylatoxin chemotactic receptor 1 (C5AR1, also known as CD88) is a G protein-coupled receptor for the anaphylatoxin C5a, a cleavage product of the complement cascade. It is involved in several processes, including the complement component C5a signaling pathway and the positive regulation of the ERK1 and ERK2 cascade. C5AR1 is activated upon binding of the C5a molecule, stimulating chemotaxis, granule enzyme release, intracellular calcium release, and superoxide anion production. It plays a crucial role in host defense and immune responses, contributing to inflammation and tissue repair. Properties Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. Synonyms C5AR, C5AR1, C5A, C5a anaphylatoxin chemotactic receptor 1, C5a R FAQ 1、I have limited sample diluent. How should I handle samples requiring high dilution factors? Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows: Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample. Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample. Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample. If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.