| Product name | Human Carbonic Anhydrase IX/CA9 ELISA Kit |
| Synonyms | CA9, CAIX, carbonic anhydrase IX, CA 9, CA IX |
| Reactivity | Human |
| Host / Isotype | United States |
| Tests | 1 X 96 well plate |
| Sample type | Serum, Plasma, Cell culture supernatant, Urine |
| Assay type | Sandwich |
| Sensitivity | 2.1 pg/mL |
| Range | 31.25-2000 pg/mL |
| Tested applications | Sandwich ELISA |
| Gene ID (NCBI) | 768 |
| Sample Type | Average Range |
| Human serum | 84% 72%-112% |
| Cell culture supernatant | 103% 99%-109% |
| Urine | 109% 103%-114% |
| Sample | n mean ( pg/mL ) SD CV% |
| 1 | 16 1,241.4 72.6 5.8 |
| 2 | 16 300.8 14.9 4.9 |
| 3 | 16 148.1 9.2 6.2 |
| Storage Instructions | All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. |
CA9 (Carbonic anhydrase 9) may be involved in the control of cell proliferation and transformation and appears to be a novel specific biomarker for a cervical neoplasia. It is a tumor-associated antigen that has been shown to have diagnostic utility in identifying cervical dysplasia and carcinoma.The protein is presentboth on the plasma membrane and in the nucleus of cells and has the molecular. Under hypoxic conditions, CA9 expression increases, helping cells adapt to the acidic environment. Properties Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. Synonyms CA9, CAIX, carbonic anhydrase IX, CA 9, CA IX FAQ 1、I have limited sample diluent. How should I handle samples requiring high dilution factors? Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows: Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample. Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample. Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample. If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.