| Product name | Human Caspase 10 ELISA Kit |
| Synonyms | CASP10, Caspase10, Apoptotic protease Mch 4, Apoptotic protease Mch-4, CASP 10 |
| Reactivity | Human |
| Host / Isotype | United States |
| Tests | 1 X 96 well plate |
| Sample type | Cell lysate |
| Assay type | Sandwich |
| Sensitivity | 9.3 pg/mL |
| Range | 78.1-5000 pg/mL |
| Tested applications | Sandwich ELISA |
| Gene ID (NCBI) | 843 |
| Sample Type | Average Range |
| Cell lysate | 102% 98%-109% |
| Sample | n mean ( pg/mL ) SD CV% |
| 1 | 16 2,684.4 128.9 4.8 |
| 2 | 16 671.9 31.2 4.6 |
| 3 | 16 344.2 15.4 4.5 |
| Storage Instructions | All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. |
Caspase-10 is a protein closely related to apoptosis. It is highly homologous to Caspase-8. As the initiator caspase, Caspase-10 plays an important role in the apoptosis pathway mediated by death receptors (such as Fas, TNF-α receptor, etc.). It is recruited and autocatalytically activated in the death-inducing signaling complex (DISC), and then activates downstream effector caspases (such as Caspase-3, -6 and -7), thereby initiating apoptosis. CASP10 deficiency is the cause of autoimmune lymphoproliferative syndrome type 2A (ALPS2A), familial non-Hodgkin's lymphoma (NHL) and gastric cancer (GASC). The full length consists of a 219-amino acid propeptide and 6 isoforms produced by alternative splicing. Properties Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. Synonyms CASP10, Caspase10, Apoptotic protease Mch 4, Apoptotic protease Mch-4, CASP 10 FAQ 1、I have limited sample diluent. How should I handle samples requiring high dilution factors? Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows: Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample. Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample. Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample. If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.