| Product name | Human CBX1 ELISA Kit |
| Synonyms | CBX1,CBX,Chromobox protein homolog 1,Heterochromat |
| Reactivity | Human |
| Host / Isotype | United States |
| Tests | 1 X 96 well plate |
| Sample type | Cell lysate |
| Assay type | Sandwich |
| Sensitivity | 0.08 ng/mL |
| Range | 0.313-20 ng/mL |
| Tested applications | Sandwich ELISA |
| Gene ID (NCBI) | 10951 |
| Sample Type | Average Range |
| Cell lysate | 113% 103%-119% |
| Sample | n mean ( ng/mL ) SD CV% |
| 1 | 16 9.52 0.59 6.15 |
| 2 | 16 2.41 0.13 5.57 |
| 3 | 16 1.27 0.09 7.36 |
| Storage Instructions | All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. |
CBX1 (Chromobox protein homolog 1), also known as CBX. It is expected to be located in nucleus, the protein is expressed in all adult and embryonic tissues. It is a member of the heterochromatin protein family. CBX1 is enriched in the heterochromatin and associated with centromeres. The protein has a single N-terminal chromodomain which can bind to histone proteins via methylated lysine residues, and a C-terminal chromo shadow-domain (CSD) which is responsible for the homodimerization and interaction with a number of chromatin-associated nonhistone proteins. It may play an important role in the epigenetic control of chromatin structure and gene expression. The calculated molecular weight of CBX1 is 21 kDa. Properties Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. Synonyms CBX1,CBX,Chromobox protein homolog 1,Heterochromat FAQ 1、I have limited sample diluent. How should I handle samples requiring high dilution factors? Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows: Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample. Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample. Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample. If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.