| Product name | Human MMP-8 ELISA Kit |
| Synonyms | MMP8,CLG1,EC:3.4.24.34,HNC,Matrix metalloproteinas |
| Reactivity | Human |
| Host / Isotype | United States |
| Tests | 1 X 96 well plate |
| Sample type | Serum, Plasma, Cell culture supernatant, Saliva,Tissue lysate |
| Assay type | Sandwich |
| Sensitivity | 4.6 pg/mL |
| Range | 39-2500 pg/mL |
| Tested applications | Sandwich ELISA |
| Gene ID (NCBI) | 4317 |
| Sample Type | Average Range |
| Human plasma | 81% 76%-90% |
| Cell culture supernatant | 80% 72%-85% |
| Saliva | 89% 80%-106% |
| Tissue lysate | 89% 80%-99% |
| Sample | n mean ( pg/mL ) SD CV% |
| 1 | 24 1,276.1 46.5 3.6 |
| 2 | 24 273.8 12.2 4.4 |
| 3 | 24 70.3 2.7 3.9 |
| Storage Instructions | All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. |
| human | Cell culture supernatant, Serum Front Immunol CCR1(+) monocytes facilitating bronchopulmonary dysplasia through regulation of S100A8 and MMP8. Authors - Yingjuan Geng View Article |
MMP-8 (Matrix metalloproteinase-8) an enzyme that degrades fibrillar collagens imparting strength to the fetal membranes, is expressed by leukocytes and chorionic cytotrophoblast cells (PMID:15367487). The high-serum MMP-8 levels (>100 ng/mL) had poor cancer-specific survival (PMID: 29808017). MMP8 also has prognosis in patients with gastric cancer (PMID: 30192205). Properties Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. Synonyms MMP8,CLG1,EC:3.4.24.34,HNC,Matrix metalloproteinas FAQ 1、I have limited sample diluent. How should I handle samples requiring high dilution factors? Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows: Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample. Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample. Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample. If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.