| Product name | Human CD164 ELISA Kit |
| Synonyms | MGC-24, MGC-24v, MUC-24, Multi-glycosylated core protein 24 |
| Reactivity | Human |
| Host / Isotype | United States |
| Tests | 1 X 96 well plate |
| Sample type | Serum, Plasma, Cell lysate |
| Assay type | Sandwich |
| Sensitivity | 0.02 ng/mL |
| Range | 0.156-10 ng/mL |
| Tested applications | Sandwich ELISA |
| Gene ID (NCBI) | 8763 |
| Sample Type | Average Range |
| Human serun | 108% 106%-109% |
| Cell lysate | 92% 86%-96% |
| Sample | n mean ( ng/mL ) SD CV% |
| 1 | 16 4.68 0.21 4.39 |
| 2 | 16 1.47 0.04 2.58 |
| 3 | 16 0.48 0.02 3.14 |
| Storage Instructions | All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. |
Sialomucins are a heterogeneous group of secreted or membrane-associated mucins that appear to play two key but opposing roles in vivo: first as cytoprotective or antiadhesive agents, and second as adhesion receptors. CD164 is a type I integral transmembrane sialomucin that functions as an adhesion receptor. It is known to function as a receptor that regulates stem cell localization to the bone marrow. Important role of CD164 in prostate cancer metastasis, promoting myogenesis and regulating myoblast migration so far been revealed. Properties Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. Synonyms MGC-24, MGC-24v, MUC-24, Multi-glycosylated core protein 24 FAQ 1、I have limited sample diluent. How should I handle samples requiring high dilution factors? Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows: Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample. Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample. Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample. If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.