| Product name | Human CD6 ELISA Kit |
| Synonyms | CD6 molecule, Soluble CD6, T12, T-cell differentiation antigen CD6, TP120 |
| Reactivity | Human |
| Host / Isotype | United States |
| Tests | 1 X 96 well plate |
| Sample type | Serum, Plasma, Cell lysate |
| Assay type | Sandwich |
| Sensitivity | 0.4 pg/mL |
| Range | 78.1-5000 pg/mL |
| Tested applications | Sandwich ELISA |
| Gene ID (NCBI) | 923 |
| Sample Type | Average Range |
| Human serum | 98% 87%-107% |
| Cell lysate | 92% 79%-99% |
| Sample | n mean ( pg/mL ) SD CV% |
| 1 | 16 2,408.3 71.0 2.9 |
| 2 | 16 597.7 31.8 5.3 |
| 3 | 16 321.8 21.2 6.6 |
| Storage Instructions | All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. |
CD6 is a lymphocyte surface accessory molecule that is associated with the T-cell receptor (TCR) complex in the immune synapse. It plays a key role in T-cell activation and proliferation by mediating cell-cell contacts and regulating T-cell responses. CD6 is involved in the stabilization and maturation of the immunological synapse, facilitating T-cell interactions with antigen-presenting cells (APCs) and subsequent T-cell proliferative responses. Additionally, CD6 has been shown to modulate T-cell activation by attenuating signaling cascades, acting as a rheostat-type signalosome that tunes T-cell activation. Properties Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. Synonyms CD6 molecule, Soluble CD6, T12, T-cell differentiation antigen CD6, TP120 FAQ 1、I have limited sample diluent. How should I handle samples requiring high dilution factors? Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows: Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample. Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample. Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample. If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.