| Product name | Human CLYBL ELISA Kit |
| Synonyms | (3S)-malyl-CoA thioesterase, Beta-methylmalate synthase, Citramalyl-CoA lyase, mitochondrial, citrate lyase beta like, Citrate lyase beta-like |
| Reactivity | Human |
| Host / Isotype | United States |
| Tests | 1 X 96 well plate |
| Sample type | Cell lysate |
| Assay type | Sandwich |
| Sensitivity | 0.01 ng/mL |
| Range | 0.78-50 ng/mL |
| Tested applications | Sandwich ELISA |
| Gene ID (NCBI) | 171425 |
| Sample Type | Average Range |
| Cell lysate | 94% 87%-100% |
| Sample | n mean ( ng/mL ) SD CV% |
| 1 | 16 12.77 0.78 6.14 |
| 2 | 16 2.86 0.11 3.97 |
| 3 | 16 1.47 0.06 3.95 |
| Storage Instructions | All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. |
CLYBL (Citrate lyase beta like), also named CLB, is a Mitochondrial citramalyl-CoA lyase indirectly involved in vitamin B12 metabolism. CLYBL exhibits malate synthase and b-methylmalate synthase activities. CLYBL was expressed at lower levels in breast cancer samples compared with normal tissues. This low CLYBL expression was associated with poor patient survival rates. Overexpressing CLYBL could inhibit breast cancer and reduce NRF2 pathway-mediated antioxidants. Properties Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. Synonyms (3S)-malyl-CoA thioesterase, Beta-methylmalate synthase, Citramalyl-CoA lyase, mitochondrial, citrate lyase beta like, Citrate lyase beta-like FAQ 1、I have limited sample diluent. How should I handle samples requiring high dilution factors? Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows: Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample. Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample. Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample. If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.