| Product name | Human DDX6 ELISA Kit |
| Synonyms | ATP-dependent RNA helicase p54, EC:3.6.4.13, HLR2, P54, Probable ATP-dependent RNA helicase DDX6 |
| Reactivity | Human |
| Host / Isotype | United States |
| Tests | 1 X 96 well plate |
| Sample type | Cell lysate |
| Assay type | Sandwich |
| Sensitivity | 0.39 ng/mL |
| Range | 1.56-100 ng/mL |
| Tested applications | Sandwich ELISA |
| Gene ID (NCBI) | 1656 |
| Sample Type | Average Range |
| Cell lysate | 111% 100%-128% |
| Sample | n mean ( ng/mL ) SD CV% |
| 1 | 16 48.94 2.84 5.79 |
| 2 | 16 12.73 0.82 6.43 |
| 3 | 16 6.70 0.42 6.25 |
| Storage Instructions | All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. |
DDX6, also named as P54, HLR2, and RCK, is a 483 amino acid protein, which contains one helicase C-terminal domain, one helicase ATP-binding domain, and belongs to the DEAD box helicase family. P54 is abundantly expressed in most tissues, in gastric cancer, DDX6 positively regulated the expression of HER2 and FGFR2 and promoted the process of c-Myc. In the process of mRNA degradation, P54 may play a role in mRNA decapping. P54 is involved in the replication of hepatitis C virus genomes in hepatocytes and in tumourigenesis of hepatocellular carcinomas. Properties Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. Synonyms ATP-dependent RNA helicase p54, EC:3.6.4.13, HLR2, P54, Probable ATP-dependent RNA helicase DDX6 FAQ 1、I have limited sample diluent. How should I handle samples requiring high dilution factors? Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows: Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample. Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample. Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample. If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.