| Product name | Human ICAM3/CD50 ELISA Kit |
| Synonyms | CDW50, ICAM3, CD50, ICAM 3, ICAM R |
| Reactivity | Human |
| Host / Isotype | United States |
| Tests | 1 X 96 well plate |
| Sample type | Serum, Plasma |
| Assay type | Sandwich |
| Sensitivity | 0.02 ng/mL |
| Range | 0.313-20 ng/mL |
| Tested applications | Sandwich ELISA |
| Gene ID (NCBI) | 3385 |
| Sample Type | Average Range |
| Human serum | 86% 82%-90% |
| Sample | n mean ( ng/mL ) SD CV% |
| 1 | 16 9.42 0.41 4.40 |
| 2 | 16 2.32 0.13 5.80 |
| 3 | 16 1.26 0.05 3.89 |
| Storage Instructions | All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. |
ICAM3 (Intercellular adhesion molecule 3) is also named as CD50, CDw50 and ICAM-R. ICAM3 is a member of the intercellular adhesion molecule (ICAM) family. ICAM3, being expressed constitutively on T cells and other leukocytes, is a potent signalling molecule and a major ligand in the initiation of T cell-mediated immune responses. ICAM3 is the natural ligand for both DC-SIGN and L-SIGN. ICAM3 is abundantly and constitutively expressed in all leukocytes and is probably the most important ligand for LFA-1 in initiating immune responses, and ICAM3 is a typical type I transmembrane glycoprotein. The promoter region of ICAM3 can be bound by co-transcription factors such as ETs and C/EBP, promoting macrophage maturation as well as monocyte extravasation. ICAM3 is widely expressed not only in lymphocytes such as T and B cells but also in many endothelial cells and dendritic cells. Properties Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. Synonyms CDW50, ICAM3, CD50, ICAM 3, ICAM R FAQ 1、I have limited sample diluent. How should I handle samples requiring high dilution factors? Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows: Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample. Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample. Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample. If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.