| Product name | Human IGFBP6 ELISA Kit |
| Synonyms | IBP 6, IBP6, IBP-6, IGF binding protein 6, IGF-binding protein 6 |
| Reactivity | Human |
| Host / Isotype | United States |
| Tests | 1 X 96 well plate |
| Sample type | Serum, Plasma, Cell lysate, Tissue lysate |
| Assay type | Sandwich |
| Sensitivity | 33.6 pg/mL |
| Range | 62.5-4000 pg/mL |
| Tested applications | Sandwich ELISA |
| Gene ID (NCBI) | 3489 |
| Sample Type | Average Range |
| Human serum | 93% 82%-98% |
| Cell lysate | 94% 79%-103% |
| Tissue lysate | 93% 85%-103% |
| Sample | n mean ( pg/mL ) SD CV% |
| 1 | 16 2,057.4 109.7 5.3 |
| 2 | 16 509.0 29.8 5.9 |
| 3 | 16 261.9 15.9 6.1 |
| Storage Instructions | All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. |
IGFBP6 is known for its identical protein binding activity and insulin-like growth factor II (IGF-II) binding activity. It plays a role in cell migration and positively regulates the stress-activated MAPK cascade. As a component of the insulin-like growth factor binary complex, IGFBP6 helps modulate the availability and activity of IGFs in the body. IGFBP6 has been implicated in obesity and serves as a biomarker for several conditions, including breast cancer, in situ carcinoma, leiomyoma, and neovascular inflammatory vitreoretinopathy. Research has shown that IGFBP6 can influence tumor progression and response to treatment in various cancer types, such as glioblastoma, ovarian cancer, and prostate cancer. Properties Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. Synonyms IBP 6, IBP6, IBP-6, IGF binding protein 6, IGF-binding protein 6 FAQ 1、I have limited sample diluent. How should I handle samples requiring high dilution factors? Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows: Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample. Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample. Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample. If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.