| Product name | Human LIF ELISA Kit |
| Synonyms | Leukemia inhibitory factor, Differentiation-stimulating factor, Melanoma-derived LPL inhibitor |
| Reactivity | Human |
| Host / Isotype | United States |
| Tests | 1 X 96 well plate |
| Sample type | Serum,Plasma,Cell culture supernatants |
| Assay type | Sandwich |
| Sensitivity | 0.3 pg/mL |
| Range | 15.6-1000 pg/mL |
| Tested applications | Sandwich ELISA |
| Gene ID (NCBI) | 3976 |
| Sample Type | Average Range |
| Human serum | 84% 70%-114% |
| Cell culture supernatant | 94% 74%-122% |
| Sample | n mean ( pg/mL ) SD CV% |
| 1 | 16 529.6 19.7 3.7 |
| 2 | 16 120.3 6.1 5.0 |
| 3 | 16 64.8 4.1 6.4 |
| Storage Instructions | All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. |
Leukemia Inhibitory Factor (LIF) is a multi-functional cytokine belonging to the interleukin-6 (IL-6) superfamily. Initially identified as a factor that inhibits the proliferation of murine myeloid leukemia cells, LIF has since been found to play important roles in various physiological and pathological processes. These include regulating cell proliferation, maintaining the self-renewal of pluripotent stem cells, tissue/organ development and regeneration, neurogenesis and neural regeneration, maternal reproduction, inflammation, immune response, and metabolism. Properties Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. Synonyms Leukemia inhibitory factor, Differentiation-stimulating factor, Melanoma-derived LPL inhibitor FAQ 1、I have limited sample diluent. How should I handle samples requiring high dilution factors? Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows: Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample. Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample. Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample. If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.