| Product name | Human LRRC32 ELISA Kit |
| Synonyms | D11S833E, GARP, Garpin, LRRC32 |
| Reactivity | Human |
| Host / Isotype | United States |
| Tests | 1 X 96 well plate |
| Sample type | Serum, Plasma, Cell culture supernatants, Tissue lysates |
| Assay type | Sandwich |
| Sensitivity | 0.52 ng/mL |
| Range | 0.94-60 ng/mL |
| Tested applications | Sandwich ELISA |
| Gene ID (NCBI) | 2615 |
| Sample Type | Average Range |
| Human Serum | 85% 78%-107% |
| Cell culture supernatants | 98% 88%-117% |
| Tissue lysates | 108% 86%-122% |
| Sample | n mean ( ng/mL ) SD CV% |
| 1 | 24 32.04 2.56 8.0 |
| 2 | 24 7.59 0.67 8.8 |
| 3 | 24 1.79 0.19 10.8 |
| Storage Instructions | All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. |
LRRC32, also known as GARP, is a transmembrane protein of 662 amino acids, the extracellular portion of which contains 20 leucine-rich repeats. LRRC32 is a cell surface receptor on regulatory T-lymphocytes (Treg cells), platelets, hepatic stellate cells and certain cancer cells. It has been demonstrated as a Treg-specific activation marker. LRRC32 is critical for the surface expression of latent TGF-β by binding to the complex and functioning as its cell surface receptor. Membrane bound LRRC32 can be shed from cell surface and exists in soluble form. Properties Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. Synonyms D11S833E, GARP, Garpin, LRRC32 FAQ 1、I have limited sample diluent. How should I handle samples requiring high dilution factors? Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows: Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample. Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample. Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample. If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.