| Product name | Human Mammaglobin A ELISA Kit |
| Synonyms | Mammaglobin 1, Mammaglobin A, MGB1, SCGB2A2, UGB2 |
| Reactivity | Human |
| Host / Isotype | United States |
| Tests | 1 X 96 well plate |
| Sample type | Serum, Plasma, Cell culture supernatants, Urine |
| Assay type | Sandwich |
| Sensitivity | 5.0 pg/mL |
| Range | 125-8000 pg/mL |
| Tested applications | Sandwich ELISA |
| Gene ID (NCBI) | 4250 |
| Sample Type | Average Range |
| Urine | 94% 85%-113% |
| Human plasma | 103% 92%-111% |
| Cell culture supernatants | 104% 86%-125% |
| Sample | n mean ( pg/mL ) SD CV% |
| 1 | 24 5,411.6 483.5 8.9 |
| 2 | 24 2,572.7 133.4 5.2 |
| 3 | 24 485.1 22.9 4.7 |
| Storage Instructions | All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. |
Mammaglobin A, also known as SCGB2A2, is a member of the secretoglobin superfamily. Mammaglobin A is expressed in normal mammary gland epithelium and is over-expressed in primary and metastatic human breast cancers, making it a specific molecular marker and a potential therapeutic target for breast cancer. Secreted Mammaglobin protein has been detected in the sera of some breast cancer patients and not in sera of patients with other tumor types, indicating Mammaglobin as a serum marker for breast cancer. Properties Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. Synonyms Mammaglobin 1, Mammaglobin A, MGB1, SCGB2A2, UGB2 FAQ 1、I have limited sample diluent. How should I handle samples requiring high dilution factors? Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows: Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample. Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample. Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample. If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.