| Product name | Human MTHFD1 ELISA Kit |
| Synonyms | C-1-tetrahydrofolate synthase, cytoplasmic, C-1-tetrahydrofolate synthase, cytoplasmic, N-terminally processed, C1-THF synthase, Epididymis secretory sperm binding protein, MTHFC |
| Reactivity | Human |
| Host / Isotype | United States |
| Tests | 1 X 96 well plate |
| Sample type | Cell lysate |
| Assay type | Sandwich |
| Sensitivity | 0.02 ng/mL |
| Range | 0.313-20 ng/mL |
| Tested applications | Sandwich ELISA |
| Gene ID (NCBI) | 4522 |
| Sample Type | Average Range |
| Cell lysate | 107% 95%-116% |
| Sample | n mean ( ng/mL ) SD CV% |
| 1 | 16 9.94 0.86 8.60 |
| 2 | 16 2.19 0.18 8.24 |
| 3 | 16 1.11 0.05 4.31 |
| Storage Instructions | All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. |
MTHFD1 is a trifunctional enzyme involved in the pathway tetrahydrofolate interconversion, which is part of One-carbon metabolism. MTHFD1 is associated with HCC and CRC progression. It has been reported that MTHFD-deficient patient fibroblasts exhibit enriched MTHFD1 in the nucleus which is critical for de novo dTMP synthesis. MTHFD1 is widely expressed in malignant prostate cancer cells, mast cells, and macrophages. Properties Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. Synonyms C-1-tetrahydrofolate synthase, cytoplasmic, C-1-tetrahydrofolate synthase, cytoplasmic, N-terminally processed, C1-THF synthase, Epididymis secretory sperm binding protein, MTHFC FAQ 1、I have limited sample diluent. How should I handle samples requiring high dilution factors? Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows: Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample. Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample. Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample. If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.