| Product name | Human Neurophysin 1 ELISA Kit |
| Synonyms | OXT, Ocytocin Neurophysin 1, Oxytocin, Oxytocin neurophysin 1, Oxytocin-neurophysin 1 |
| Reactivity | Human |
| Host / Isotype | United States |
| Tests | 1 X 96 well plate |
| Sample type | Serum, Plasma |
| Assay type | Sandwich |
| Sensitivity | 0.8 pg/mL |
| Range | 31.25-2000 pg/mL |
| Tested applications | Sandwich ELISA |
| Gene ID (NCBI) | 5020 |
| Sample Type | Average Range |
| Human serum | 98% 95%-101% |
| Sample | n mean ( pg/mL ) SD CV% |
| 1 | 16 1,033.2 29.5 2.9 |
| 2 | 16 272.4 13.5 5.0 |
| 3 | 16 135.5 6.4 4.8 |
| Storage Instructions | All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. |
Neurophysin-1 is a small molecule carrier protein, which plays a key role in the neuroendocrine system. Its main function is to combine with oxytocin, synthesize, store, transport and release it into the blood. Together with oxytocin, it is transcribed and translated into a "pre-pro-oxytocin-neurohypophysin" polypeptide chain by neurons in hypothalamic paraventricular nucleus and supraoptic nucleus. After enzyme digestion, mature oxytocin and Neurophysin 1 are produced, while Neurophysin 2 is combined with vasopressin, and their functions are separated, regulating reproduction/lactation, water-salt balance and blood pressure respectively. Properties Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. Synonyms OXT, Ocytocin Neurophysin 1, Oxytocin, Oxytocin neurophysin 1, Oxytocin-neurophysin 1 FAQ 1、I have limited sample diluent. How should I handle samples requiring high dilution factors? Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows: Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample. Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample. Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample. If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.