| Product name | Human Ninein ELISA Kit |
| Synonyms | NIN, Glycogen synthase kinase 3 beta-interacting protein, GSK3B interacting protein, GSK3B-interacting protein, hNinein |
| Reactivity | Human |
| Host / Isotype | United States |
| Tests | 1 X 96 well plate |
| Sample type | Cell lysate |
| Assay type | Sandwich |
| Sensitivity | 0.4 pg/mL |
| Range | 62.5-4000 pg/mL |
| Tested applications | Sandwich ELISA |
| Gene ID (NCBI) | 51199 |
| Sample Type | Average Range |
| Cell lysate | 87% 83%-92% |
| Sample | n mean ( pg/mL ) SD CV% |
| 1 | 16 2,105.5 97.6 4.6 |
| 2 | 16 494.4 19.8 4.0 |
| 3 | 16 249.8 17.4 7.0 |
| Storage Instructions | All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. |
Ninein is a large coiled-coil protein that associates with the subdistal appendages of the mother centriole and the minus-ends of both centrioles. Ninein is a microtubule (MT)-anchoring protein and interacts with γ-tubulin and microtubule nucleation and anchoring at the centrosomes. Ninein is a large regulatory centrosomal protein that specifically associates with the mature mother centriole during asymmetric cell division. A novel form of microcephalic primordial dwarfism disorder is associated with variants in the centrosomal protein ninein. Properties Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. Synonyms NIN, Glycogen synthase kinase 3 beta-interacting protein, GSK3B interacting protein, GSK3B-interacting protein, hNinein FAQ 1、I have limited sample diluent. How should I handle samples requiring high dilution factors? Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows: Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample. Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample. Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample. If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.