| Product name | Human NRG1, isoform Alpha ELISA Kit |
| Synonyms | NRG1, NRG1A, ARIA, GGF, GGF2 |
| Reactivity | Human |
| Host / Isotype | United States |
| Tests | 1 X 96 well plate |
| Sample type | Serum, Plasma, Cell lysate |
| Assay type | Sandwich |
| Sensitivity | 0.05 ng/mL |
| Range | 0.156-10 ng/mL |
| Tested applications | Sandwich ELISA |
| Gene ID (NCBI) | 3084 |
| Sample Type | Average Range |
| Human serum | 81% 79%-84% |
| Cell lysate | 110% 98%-121% |
| Sample | n mean ( ng/mL ) SD CV% |
| 1 | 16 5.18 0.37 7.13 |
| 2 | 16 1.23 0.06 4.64 |
| 3 | 16 0.64 0.03 4.62 |
| Storage Instructions | All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. |
| human | Serum Neural Regen Res Macrophages-derived NRG-1 promotes angiogenesis after ischemic stroke via the Akt-mTOR pathway. Authors - Jie Chen View Article |
NRG1 (Neuregulin-1) belongs to the neuregulin family of growth factors responsible for cardiac development and cardiac protection from stress and is a protein that plays a central role in cell signaling in the heart, mammary gland, and central nervous system. NRG1 has been implicated in neural development, neurotransmission, and synaptic plasticity. NRG1 and its receptor ErbB tyrosine kinase are expressed not only in the developing nervous system, but also in the adult brain. NRG1 has multiple isoforms that are generated by usage of different promoters and alternative splicing of a single gene. Properties Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. Synonyms NRG1, NRG1A, ARIA, GGF, GGF2 FAQ 1、I have limited sample diluent. How should I handle samples requiring high dilution factors? Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows: Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample. Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample. Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample. If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.
Publications