| Product name | Human PROCR/EPCR/CD201 ELISA Kit |
| Synonyms | CD201, EPCR, PROCR, Activated protein C receptor, APC receptor |
| Reactivity | Human |
| Host / Isotype | United States |
| Tests | 1 X 96 well plate |
| Sample type | Serum, Plasma |
| Assay type | Sandwich |
| Sensitivity | 6.2 pg/mL |
| Range | 31.25-2000 pg/mL |
| Tested applications | Sandwich ELISA |
| Gene ID (NCBI) | 10544 |
| Sample Type | Average Range |
| Human plasma | 108% 102%-121% |
| Sample | n mean ( pg/mL ) SD CV% |
| 1 | 16 1,001.0 40.6 4.1 |
| 2 | 16 250.9 20.2 8.1 |
| 3 | 16 139.6 20.6 14.8 |
| Storage Instructions | All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. |
| FH franck (Verified Customer) (06-03-2026) | The ELISA assay is very quick and simple. Detection was performed in conditioned media from cultured human aortic endothelial cells as well as in cell lysates (RIPA lysis). Applications: Other Cell Tissue Type: teloHAEC |
EPCR (endothelial cell protein C receptor), also known as CD201, is a type 1 transmembrane protein that is primarily found on endothelial cells. It exhibits sequence and three-dimensional structural homology with the major histocompatibility class 1/CD1 family of proteins, particularly CD1d. It binds activated protein C and enhances protein C activation by the thrombin-thrombomodulin complex. It plays a role in the protein C pathway controlling blood coagulation. Properties Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. Synonyms CD201, EPCR, PROCR, Activated protein C receptor, APC receptor FAQ 1、I have limited sample diluent. How should I handle samples requiring high dilution factors? Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows: Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample. Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample. Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample. If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.