| Product name | Human RB1CC1 ELISA Kit |
| Synonyms | CC1, FAK family kinase-interacting protein of 200 kDa, KIAA0203, RB1CC 1, RB1-inducible coiled-coil protein 1 |
| Reactivity | Human |
| Host / Isotype | United States |
| Tests | 1 X 96 well plate |
| Sample type | Cell lysate |
| Assay type | Sandwich |
| Sensitivity | 4.2 pg/mL |
| Range | 46.88-3000 pg/mL |
| Tested applications | Sandwich ELISA |
| Gene ID (NCBI) | 9821 |
| Sample Type | Average Range |
| Cell lysate | 106% 100%-115% |
| Sample | n mean ( pg/mL ) SD CV% |
| 1 | 16 1,617.7 99.5 6.1 |
| 2 | 16 418.1 18.1 4.3 |
| 3 | 16 179.8 9.6 5.3 |
| Storage Instructions | All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. |
RB1CC1 is implicated in the regulation of RB1 expression and functions as a DNA-binding transcription factor. It is a potent regulator of the RB1 pathway and a mediator that plays a crucial role in muscular differentiation. Its expression is, thus, a prerequisite for myogenic differentiation. Involved in autophagy. RB1CC1 is required for autophagosome formation. It is probably involved in the tumorigenesis of breast cancer. RB1CC1 is frequently mutated in breast cancer and shows characteristics of a classical tumor suppressor gene. Properties Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. Synonyms CC1, FAK family kinase-interacting protein of 200 kDa, KIAA0203, RB1CC 1, RB1-inducible coiled-coil protein 1 FAQ 1、I have limited sample diluent. How should I handle samples requiring high dilution factors? Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows: Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample. Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample. Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample. If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.