| Product name | Human RFC1 ELISA Kit |
| Synonyms | A1, A1 140 kDa subunit, Activator 1 140 kDa subunit, Activator 1 large subunit, Activator 1 subunit 1 |
| Reactivity | Human |
| Host / Isotype | United States |
| Tests | 1 X 96 well plate |
| Sample type | Cell lysate |
| Assay type | Sandwich |
| Sensitivity | 0.06 ng/mL |
| Range | 0.156-10 ng/mL |
| Tested applications | Sandwich ELISA |
| Gene ID (NCBI) | 5981 |
| Sample Type | Average Range |
| Cell lysate | 77% 70%-83% |
| Sample | n mean ( ng/mL ) SD CV% |
| 1 | 16 5.00 0.43 8.55 |
| 2 | 16 1.31 0.06 4.87 |
| 3 | 16 0.62 0.03 5.61 |
| Storage Instructions | All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. |
Replication factor C subunit 1 (RFC1) is a key component of the replication factor C (RFC) complex, which is essential for DNA replication and repair. The RFC complex functions as a DNA-dependent ATPase that catalyzes the opening of the DNA-clamp protein proliferating cell nuclear antigen (PCNA), allowing it to encircle DNA and act as a scaffold to recruit DNA polymerases and other proteins involved in DNA replication and repair. RFC1 is also involved in various DNA damage response pathways, including DNA damage recognition, recruitment of DNA repair machinery, base and nucleotide excision repair, mismatch repair, and promotion of cell survival. Properties Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. Synonyms A1, A1 140 kDa subunit, Activator 1 140 kDa subunit, Activator 1 large subunit, Activator 1 subunit 1 FAQ 1、I have limited sample diluent. How should I handle samples requiring high dilution factors? Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows: Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample. Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample. Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample. If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.