| Product name | Human RGS12 ELISA Kit |
| Synonyms | Regulator of G-protein signaling 12 |
| Reactivity | Human |
| Host / Isotype | United States |
| Tests | 1 X 96 well plate |
| Sample type | Cell lysate |
| Assay type | Sandwich |
| Sensitivity | 2.8 pg/mL |
| Range | 39-2500 pg/mL |
| Tested applications | Sandwich ELISA |
| Gene ID (NCBI) | 6002 |
| Sample Type | Average Range |
| Cell lysate | 96% 91%-102% |
| Sample | n mean ( pg/mL ) SD CV% |
| 1 | 16 1,263.3 75.2 6.0 |
| 2 | 16 282.2 14.0 4.9 |
| 3 | 16 136.5 5.7 4.2 |
| Storage Instructions | All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. |
RGS12 (Regulator of G-protein Signaling 12) belongs to the superfamily of RGS proteins defined by a conserved RGS domain that canonically binds and deactivates heterotrimeric G-proteins. It negatively regulates G-protein-coupled receptor (GPCR) signaling by accelerating GTP hydrolysis on Gα subunits. Unlike typical RGS proteins, RGS12 uniquely integrates multiple signaling domains, including a PDZ domain, PTB domain, and Ras-binding domain (RBD), enabling it to orchestrate cross-talk between GPCRs, receptor tyrosine kinases (RTKs), and mitogen-activated protein kinase (MAPK) pathways. It plays critical roles in neuronal development, osteoclast differentiation, and immune response by modulating calcium channels, transcription factors, and cell cycle progression. Properties Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. Synonyms Regulator of G-protein signaling 12 FAQ 1、I have limited sample diluent. How should I handle samples requiring high dilution factors? Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows: Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample. Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample. Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample. If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.