| Product name | Human ROR1 ELISA Kit |
| Synonyms | ROR1,Inactive tyrosine-protein kinase transmembran |
| Reactivity | Human |
| Host / Isotype | United States |
| Tests | 1 X 96 well plate |
| Sample type | Cell lysate |
| Assay type | Sandwich |
| Sensitivity | 0.09 ng/mL |
| Range | 0.625-40 ng/mL |
| Tested applications | Sandwich ELISA |
| Gene ID (NCBI) | 4919 |
| Sample Type | Average Range |
| Cell lysate | 115% 109%-120% |
| Sample | n mean ( ng/mL ) SD CV% |
| 1 | 16 19.16 1.22 6.34 |
| 2 | 16 4.41 0.30 6.82 |
| 3 | 16 2.22 0.15 6.74 |
| Storage Instructions | All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. |
ROR1 is a transmembrane receptor that contains an extracellular section, a transmembrane segment, and a cytoplasmic region, a member of the RTK family of orphan receptors related to muscle-specific kinase and Trk neurotrophin receptors. ROR1 is primarily expressed by neural crest cells during embryogenesis. High expression of ROR1 is reported in many malignancies and is thought to be involved in tumor growth, apoptosis, and epithelial-mesenchymal transition. Moreover, ROR1 is also involved in the activation of signaling proteins important for cell proliferation, survival, and migration. Properties Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. Synonyms ROR1,Inactive tyrosine-protein kinase transmembran FAQ 1、I have limited sample diluent. How should I handle samples requiring high dilution factors? Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows: Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample. Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample. Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample. If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.