| Product name | Human Securin ELISA Kit |
| Synonyms | PTTG1, EAP1, Esp1-associated protein, hPTTG, Pituitary tumor-transforming gene 1 protein |
| Reactivity | Human |
| Host / Isotype | United States |
| Tests | 1 X 96 well plate |
| Sample type | Cell lysate |
| Assay type | Sandwich |
| Sensitivity | 0.05 ng/mL |
| Range | 0.313-20 ng/mL |
| Tested applications | Sandwich ELISA |
| Gene ID (NCBI) | 9232 |
| Sample Type | Average Range |
| Cell lysate | 84% 79%-88% |
| Sample | n mean ( ng/mL ) SD CV% |
| 1 | 16 9.57 1.11 11.56 |
| 2 | 16 2.59 0.12 4.79 |
| 3 | 16 1.52 0.05 2.98 |
| Storage Instructions | All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. |
Securin, also known as PTTG1, is a 22 kDa protein crucial for maintaining genomic stability by preventing premature sister chromatid separation during mitosis. It is a proto-oncogene first identified in rat pituitary tumor cells and is overexpressed in various cancers, including those of the pituitary gland, kidney, and colorectal cancer. Securin plays a key role in cell cycle progression and is involved in tumorigenesis, metastasis, and resistance to cancer treatments. Additionally, Securin interacts with p53 and modulates its transcriptional activity. Its expression is associated with poor prognosis in multiple malignancies and may serve as a potential biomarker for cancer diagnosis and treatment. Properties Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. Synonyms PTTG1, EAP1, Esp1-associated protein, hPTTG, Pituitary tumor-transforming gene 1 protein FAQ 1、I have limited sample diluent. How should I handle samples requiring high dilution factors? Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows: Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample. Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample. Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample. If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.