| Product name | Human STAU1 ELISA Kit |
| Synonyms | Double-stranded RNA-binding protein Staufen homolog 1, STAU |
| Reactivity | Human |
| Host / Isotype | United States |
| Tests | 1 X 96 well plate |
| Sample type | Cell lysate |
| Assay type | Sandwich |
| Sensitivity | 0.12 ng/mL |
| Range | 0.39-25 ng/mL |
| Tested applications | Sandwich ELISA |
| Gene ID (NCBI) | 6780 |
| Sample Type | Average Range |
| Cell lysate | 112% 109%-113% |
| Sample | n mean ( ng/mL ) SD CV% |
| 1 | 16 12.28 0.46 3.74 |
| 2 | 16 3.07 0.24 7.97 |
| 3 | 16 1.58 0.11 6.72 |
| Storage Instructions | All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. |
STAU1 (Staufen Double-Stranded RNA Binding Protein 1) is a highly conserved multifunctional double-stranded RNA binding protein that is widely involved in a variety of cellular processes. STAU1 is involved in the transport of mRNA from the nucleus to the cytoplasm. In neurons, STAU1 promotes the transport and translation of mRNA by binding to the 3' untranslated region (3'UTR) of mRNA. STAU1 inhibits the retention of these mRNAs in the nucleus by binding to the inverted repeat Alu element (IRAlus) on mRNA, thereby enhancing its nuclear export; STAU1 also induces translation-dependent mRNA degradation (SMD) through direct interaction with UPF1, a process that is critical for gene expression regulation. Properties Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions. Synonyms Double-stranded RNA-binding protein Staufen homolog 1, STAU FAQ 1、I have limited sample diluent. How should I handle samples requiring high dilution factors? Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows: Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample. Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample. Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample. If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.